Appendix: Installation

Appendix: Installation

1.SUMMARY

1.1 Notice

This operation manual has explicit information for installation and maintenance in most conditions. Contact the local distributor or after-sales service for further information.

1) Wiring notice

Only qualified professionals should carry out wiring of the appliance.

Disconnect the power supply before completion of wiring, piping or checking the appliance.

1.SUMMARY Voltages generated by the appliance is fatal.

Read the electrical schematic diagram and explanation before installation. Improper installation and earth connection may result in fatal injury.

1.1 Notice C onnect the earth as required by local regulations.

Tightly fasten all the wiring connections to prevent overheating or fire.

Special power, switches and sockets are required for the power supply of the appliance.

1.2 Installing instruction Electric meter capacity must be larger than or equivalent to 16A.

Remark per EMC Directive 89/336/EEC

To prevent flicker impression during the start of the compressor (Technical Process) and the adversely influence caused by the 2nd harmonics of compressor following installation conditions do apply

1.The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of a low impedance is reached at 32A fusing point.

2.No other equipment has to be connected to this power line.

3.For the detailed installation acceptance please refer to your contract with the power supplier, if restrictions do apply for products like washing machines, air conditioners or electrical ovens.

4.For the details of the power of air conditioner, please refer to the rating plate of the product.

5.For any question contact your local dealer.

2). Transport

Manual background Carefully move the outdoor unit.

3). Installation

----When the appliance is mounted to the ceiling or the wall,

Manual background Make sure that the ceiling or the wall is strong enough for the appliance.

Make a wood or metal frame to support the appliance if necessary.

----When the appliance is mounted in a room,

Manual background Properly insulate the outdoor unit, and make sure there is no moisture on the appliance or on the floor.

----When the appliance is installed on a damp or uneven area,

Make a flat concrete base and place the base under the outdoor unit.

----When the appliance is installed in an area of strong winds.

Manual background Using firm bolts and metal frames to fix the properly covered outdoor unit.

----When the appliance (Model Heat Pump) is installed in an

area of heavy snow.

Manual background The outdoor unit must be installed in a position above the snow accumulation.

4). Connection

Manual background Use the shortest tubes possible

Manual background Using a flaring method

Manual background Smear some refrigeration oil between the flared surface and the connected tube.

Fasten the nuts with a torque wrench to prevent leakage of refrigerant.

Manual background Check for leakage before trial operation.

5). Maintenance

Manual background Disconnect the power before checking the electrical components andthe circuits.

Manual background Avoid contact with the moving parts of the appliance.

Manual background Clear the site and make sure there is no installation debris left in the appliance.

6). Other

Manual background Keep the room well ventilated during installation.

1.2 Installing instruction

Read the operation manual before installation and keep this manual in a safe place.

1)Tools

1.Screwdriver

2.Phillips head screwdriver

3.Knife or wire stripper

4.Steel ruler

5.Spirit level

6.Hammer

7.Percussion drill

8.Tube cutter

9.Pipe flarer

10.Pipe bender

11.Adjustable spanner

2)Attachment

(see thepacking list)

3)Parts Package

Copper tubes, components and insulation materials for the outdoor unit.

4)Type of the copper tube and insulation materials

1.Table 1 indicates that tubes should be cut with an additional length of 30cm-40cm, to reduce the vibration from the outdoor unit.

ITEM

Narrow tube

Wide tube

Outside Diameter

Thickness

Outside Diameter

Thickness

 

KF-5002GWE

6.35mm

0.8mm

12.7mm

0.8mm

 

 

 

 

 

2.The insulation materials for the copper tubes should conform to the required length and the wall thickness should not be less than 8mm.

3.Insulated copper wires should be used for wiring and the specification should depend on the length.

5)Additional materials for installation

1. white tape

2. nails or clips (as required)

3. putty

4. refrigeration oil

5. clips for fixing refrigerant tubes

22