7K200 SATA OEM Specification

14.44Write DMA Ext (35h)

 

Command Block Output Registers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register

 

 

 

7

 

 

6

 

 

5

 

 

4

 

 

3

 

 

2

 

 

1

 

0

 

Register

 

 

 

7

 

 

 

6

 

5

 

 

4

3

 

 

 

2

 

1

 

 

 

0

 

Data Low

 

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

Data Low

 

 

 

-

 

-

 

-

 

-

-

 

-

 

-

 

-

 

Data High

 

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

Data High

 

 

 

-

 

-

 

-

 

-

-

 

-

 

-

 

-

 

Feature

 

 

Current

 

-

 

 

-

 

 

-

 

 

-

 

 

-

 

 

-

 

 

-

 

-

 

Error

 

 

 

 

 

 

 

 

 

 

 

...See Below...

 

 

 

 

 

 

 

 

 

 

Previous

 

-

 

 

-

 

 

-

 

 

-

 

 

-

 

 

-

 

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sector Count

Current

 

V

 

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

V

 

Sector Count

 

HOB=0

-

 

-

 

-

 

-

-

 

 

-

 

-

 

 

-

 

 

 

 

 

Previous

 

V

 

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

V

 

 

 

 

 

 

HOB=1

-

 

 

-

 

-

 

-

-

 

 

-

 

-

 

 

 

-

 

LBA Low

Current

 

V

 

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

V

 

LBA Low

 

HOB=0

V

 

 

V

 

V

 

V

V

 

V

 

V

 

 

V

 

 

 

 

 

Previous

 

V

 

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

V

 

 

 

 

 

 

HOB=1

V

 

 

V

 

V

 

V

V

 

V

 

V

 

 

V

 

LBA Mid

Current

 

V

 

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

V

 

LBA Mid

 

HOB=0

V

 

 

V

 

V

 

V

V

 

V

 

V

 

 

V

 

 

 

 

 

Previous

 

V

 

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

V

 

 

 

 

 

 

HOB=1

V

 

 

V

 

V

 

V V V

V

 

 

V

 

LBA High

Current

 

V

 

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

V

 

LBA High

 

HOB=0

V

V

V

V

V

V

V

V

 

 

 

 

 

Previous

 

V

 

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

 

V

 

V

 

 

 

 

 

 

HOB=1

V

 

 

 

V

 

V

 

 

V

V

 

 

 

V

V

 

 

 

V

 

Device

 

 

 

 

-

 

1

 

-

 

-

 

-

 

-

 

-

 

-

 

Device

 

 

 

-

 

-

 

-

 

-

-

 

-

 

-

 

-

 

Command

 

 

0

 

0

 

1

 

1

 

0

 

1

 

0

 

1

 

Status

 

 

 

 

 

 

 

 

 

...See Below...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

6

 

5

4

3

 

 

 

 

2

 

 

 

1

 

 

 

0

 

 

7

 

6

 

5

 

4

 

3

 

 

2

 

1

 

 

0

 

CRC

 

UNC

 

0

IDN

0

 

 

 

ABT

 

 

T0N

 

 

AMN

 

BSY

 

RDY

 

DF

DSC

DRQ

 

COR

IDX

ERR

 

V

 

0

 

0

V

0

 

 

 

 

 

V

 

 

 

0

 

 

 

0

 

 

0

 

V

 

0

 

V

 

-

 

 

0

 

0

 

 

V

Table 128 Write DMA Ext Command (35h)

The Write DMA Ext command transfers one or more sectors of data from the host to the device, then the data is written to the disk media.

The sectors of data are transferred through the Data Register 16 bits at a time.

The host initializes a slave-DMA channel prior to issuing the command. Data transfers are qualified by DMARQ and are performed by the slave-DMA channel. The device issues only one interrupt per command to indicate that data transfer has terminated and status is available.

If an uncorrectable error occurs, the write will be terminated at the failing sector

Output Parameters To The Device

Sector Count Current

The number of continuous sectors to be transferred low order, bits (7:0).

Sector Count Previous

The number of continuous sectors to be transferred high order bits (15:8). If 0000h in

 

the Sector Count register is specified, then 65,536 sectors will be transferred.

LBA Low Current

LBA (7:0).

LBA Low Previous

LBA (31:24).

LBA Mid Current

LBA (15:8).

LBA Mid Previous

LBA (39:32).

LBA High Current

LBA (23:16).

LBA High Previous

LBA (47:40).

Input Parameters From The

Device

LBA Low (HOB=0)

LBA (7:0) of the address of the first unrecoverable error.

LBA Low (HOB=1)

LBA (31:24) of the address of the first unrecoverable error.

LBA Mid (HOB=0)

LBA (15:8) of the address of the first unrecoverable error.

LBA Mid (HOB=1)

LBA (39:32) of the address of the first unrecoverable error.

LBA High (HOB=0)

LBA (23:16) of the address of the first unrecoverable error.

LBA High (HOB=1)

LBA (47:40) of the address of the first unrecoverable error.