Hitachi HUS103014FL3600, HUS103036FL3600 specifications Physical interface, 1 Interface connectors

Models: HUS103073FL3800 HUS103030FL3600 HUS103073FL3600 HUS103036FL3800 HUS103030FL3800 HUS103014FL3800 HUS103014FL3600 HUS103036FL3600

1 43
Download 43 pages 37.05 Kb
Page 29
Image 29
10Physical interface

10Physical interface

10.1Connector Specifications

Use the mating connectors which are electrically and mechanically compatible. The following part numbers indicate the mating connectors.

Table 10.1 Interface connectors

Interface

Name

Part number

Manufacturer

WIDE LVD

SCSI interface connector

786090-7

AMP

 

 

DHJ-PAC68-2AN

DDK

 

DC power connector

Pin:61314-4

AMP

 

 

Housing:1-480424-0

AMP

SCA-2 LVD

SCSI interface connector

787311-1

AMP

 

with DC power connector

787565-1

AMP

 

 

HD2-PA080-S11

DDK

10.2Cable Specifications

(1)SCSI Interface Cable

Use interface cables that meet the ANSI SCSI guideline.

The total cable length must be within the maximum cable length in case multiple drives are daisy chained. Specifications of maximum cable length are shown in Table 10.2 and Table 10.3.

The length of a cable connected between SCSI devices must be a minimum of 12 cm. (The stub length of the drive: 4 cm)

If an external cable the stub length of which becomes long is connected

to the devices, the cable length between the devices must be a minimum of (external stub length + 4 cm) x 3.

If data are transferred by Ultra SCSI (Fast-20) mode, Ultra2 SCSI (Fast-40) mode, Ultra160 SCSI (Fast-80) mode or Ultra320 SCSI (Fast-160) mode, check that the interface reflection noise does not influence the motion of the drive in the actual user’s system.

Drawing No. Sheet No. Revision

K6610091

29/43

2005/2/23

Page 29
Image 29
Hitachi HUS103014FL3600, HUS103036FL3600, HUS103030FL3800, HUS103073FL3800 Physical interface, 1 Interface connectors