12.2.2Disable Auto Start

WIDE LVD

No.

Option Jumper Connector (C3)

Meaning

1

Remove the Jumper Socket

Spindle motor automatically

starts when the power is

 

for C3-9,10 (Default)

 

 

 

applied or in sequence via ID

 

 

 

 

 

1

9

23

number x 10 seconds from the

 

time power is applied if

 

 

 

 

 

 

 

 

C3-13,14 is jumpered.

 

2

10

24

 

2

Install the Jumper Socket

Spindle motor starts only

 

for C3-9,10

 

by SCSI command

 

1

9

23

 

 

2

10

24

 

12.2.3Force Single-Ended bus mode

WIDE LVD

No.

Option Jumper Connector (C3)

Meaning

1

Remove the Jumper Socket

The drive can be used as

 

for C3-11,12 (Default)

 

single-ended or low voltage

 

1

11

23

differential mode.

 

 

 

2

12

24

 

2

Install the Jumper Socket

 

The drive is forced to operate

 

for C3-11,12

 

only in single-ended mode.

 

1

11

23

 

 

2

12

24

 

Drawing No. Sheet No. Revision

K6610091

40/43

2005/2/23

Page 40
Image 40
Hitachi HUS103036FL3600, HUS103030FL3800, HUS103073FL3800, HUS103036FL3800, HUS103073FL3600, HUS103014FL3600 Wide LVD