12.2.4Enable Delayed Start

WIDE LVD

No.

Option Jumper Connector (C3)

 

Meaning

1

 

Remove the Jumper Socket

Spindle motor automatically

 

 

for C3-13,14 (Default)

 

starts when the power is on.

 

1

13

23

 

 

 

2

14

24

 

 

2

 

Install the Jumper Socket

Spindle motor starts in

 

 

for C3-13,14

 

sequence via ID number x 10

 

1

13

23

seconds from the time power is

 

applied

(NOTE 1)

 

 

 

 

 

 

 

 

 

 

2

14

24

 

 

Note 1. This time is as follows:

ID number 0 to 7 : ID number x 10sec

ID number 8 to 15 : (ID number - 8) x 10sec

Note 2. This jumper is valid only when Auto Start setting is done.

Note 3. If setting for Delayed Start is done by host via SCSI bus connector (C1) in SCA-2 LVD drive, remove jumper in C3-13,14.

Note 4. If DELAY START in SCSI bus connector (C1) in SCA-2 LVD drive is grounded by host, jumper setting in C3-13,14 is invalid.

Drawing No. Sheet No. Revision

K6610091

41/43

2005/2/23

Page 41