Conveyor Drive Chain
Inspect the drive chain (Fig. 36) regularly and lubricate as required with Hykogeen Concentrate A (supplied).
Conveyor Shaft Flange Bearings
Located at both load and unload ends of the machine and at the front and back, these bearings should be lubricated every four months. Grease fittings at each of the four bearings, a grease gun and 16 ounces of Chevron SRI #2 grease are provided for this purpose. Fig. 37 shows one of the
CONVEYOR
GREASE FITTING
GREASE
FITTING
LUBRICATE GUIDES
Fig. 37 | Fig. 38 |
Conveyor Take-Up Unit
Lubricate the two conveyor
CONVEYOR SPEED ADJUSTMENT
The conveyor speed comes preset from the factory. Conveyor speed can be adjusted to run faster or slower by the customer. Refer to User Programming, pages 15 – 19.
– 21 –