Hobart FT900SBD, FT900SDBD, FT900DBD Symptom, Possible Cause, Display Reads, Possible Resolution

Models: FT900 FT900BD FT900S FT900D FT900DBD FT900SD FT900SBD FT900SDBD

1 28
Download 28 pages 48.53 Kb
Page 25
Image 25
Display Reads

SYMPTOM

POSSIBLE CAUSE

 

NOTE: If symptom(s) persist after possible causes have been checked, contact

 

Hobart Service.

 

 

Display Reads

Possible Resolution

 

 

Door(s) Open

Close all inspection doors.

 

 

Unload Dishes

Remove all ware from unload section of the machine, starting with the ware closest

 

to the machine chambers. Finally remove the last ware that is in contact with the dish

 

limit bar.

 

 

Temp Err - [Tank Name]

Ensure lower float assembly in indicated tank is not visibly damaged and sufficient

 

water is in the tank to cover the lower float.

 

 

 

Fnl Rinse Temp Low

1.

If problem is intermittent and only occurs after the machine has been idle for

 

 

several minutes, this is normal. The problem will correct itself after running

 

 

several pieces of ware through the machine.

 

2.

Check that the final rinse booster tank circuit breaker is on and not tripped (if

 

 

equipped.)

 

3.

Check that the final rinse booster tank overtemp circuit is not tripped (if equipped).

 

4.

Ensure that the building supply water to the final rinse booster tank is at least the

 

 

minimum specified by the booster manufacturer.

 

 

Temp Err - Fnl Rns

Ensure that the supply water valve to the final rinse booster is open.

 

 

 

Check Water Level

1.

Ensure all drains are closed and free of debris.

 

2.

Check that water supply valve is open

 

3.

Open inspection doors and check water level of all tanks. Watershould be

 

 

about 1 inch down from top of strainer pan or higher . Do not forget to check

 

 

the water level of the dual rinse tank (models FT900D or FT900SD) which is

 

 

located behind the control box directly beneath the final rinse arms. Close

 

 

inspection doors.

 

4.

If tanks fail to fill after another 20 minutes, contact Hobart Service.

 

 

Reset Required

Place machine in Standby by pressing the Power key. Wait at least 60 seconds

 

before powering on the machine.

 

 

 

– 25 –