ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS

WARNING: THE POWER CORD IS PROVIDED WITH A GROUNDING PLUG. THE OUTLET TO WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THIS PLUG.

Your gas convection oven is equipped with a 120 volt / 60 Hz. / 1 phase cord and plug and requires only that it be plugged into a properly grounded 120 volt receptacle.

A wiring diagram is located on the inside of the right side panel.

GAS AND ELECTRICAL DATA

 

 

 

GAS DATA

 

ELECTRICAL DATA

MODEL

INPUT BTU/HR

 

MANIFOLD PRESSURE

AMP/LINE

 

Natural

Propane

 

Natural

Propane

120 Volts

DGC1

40,000

40,000

 

3.5" W.C. (0.8 kPa)

10" W.C. (2.5 kPa)

10 Amps

HGC40/HGC60

40,000

40,000

 

3.5" W.C. (0.8 kPa)

10" W.C. (2.5 kPa)

10 Amps

HGC40D/HGC60D

40,000

40,000

 

3.5" W.C. (0.8 kPa)

10" W.C. (2.5 kPa)

10 Amps

Stacked ovens require double BTU/Hr and double amperage.

GAS CONNECTIONS

Gas supply connections and pipe joint compound must be suitable for sealing piping for propane or natural gases.

The oven is provided with a regulator integral to the gas solenoid valve and requires no external regulator.

The manual gas shutoff valve is located at the bottom of the front control panel.

The oven should be connected to the gas line after leveling. The gas supply line must be at least the equivalent of 3/4" (19mm) iron pipe. Make sure piping is clean and free of obstructions, dirt or pipe joint compound.

WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.

TESTING THE GAS SUPPLY SYSTEM

The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.45 kPa).

The oven must be isolated from the gas supply piping system by closing the manual shutoff valve during pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).