MAINTENANCE

MAINTENANCE

WARNING: THE RANGE AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE RANGE.

WARNING: (CONVECTION OVENS ONLY) DISCONNECT ELECTRICAL POWER SUPPLY BEFORE SERVICING THE RANGE.

LUBRICATION

The MGR36C convection oven motor is permanently lubricated and will not require any additional maintenance.

OVEN DOOR GASKET REPLACEMENT - CONVECTION OVEN ONLY

To remove the old gasket, gently pry the arrow-like gasket pins from the oven front frame using a standard screwdriver.

Install new gasket by aligning and inserting the arrow-like pins into the holes provided in the front frame (Fig's. 21 & 22).

Fig. 21

Fig. 22

VENT

The vent, when cool, should be checked for obstructions every six months.

ADJUSTMENTS

All adjustment procedures associated with pilot lighting must be performed by a qualified Hobart installation or service person.

Contact your local Hobart service office for any other maintenance required.