25
a) All required safety measures are taken to ensure correct lifting and handling to avoid risk of
injury through dropping, falling and tilting.
b) No damage occurs to the machine, which could impair the normal operation.
6.17 LOCATION.
The mixer is not suitable for outdoor installation and must not be installed where a water
jet could be used for cleaning. The mixer must only be operated by trained staff and
must be installed in an area where the use and maintenance is restricted to trained
personnel.
The mixer must be installed on a horizontal flat surface level to a minimum of 1mm in 1 metre side to
side and front to back. Select a suitable flat level surface that can support the weight of the mixer
and bowl contents when full (refer to Table 1 for weights and dimensions). In areas where stability
may be an issue, the machine should be secured in position.
Ensure there is sufficient space around the mixer for the user to operate the controls and to install
and remove bowls. The area above and to the rear side of the mixer should allow the top and rear
covers to be removed for routine maintenance and servicing. Servicing may be more difficult
because of reduced clearances and you should always check that equipment specifications permit
the close proximity of other equipment. Refer to Fig. 15, page 23 for the overall dimensions of the
mixer and the clearance required to accommodate the hinged bowl.
6.18 ELECTRICAL INSTALLATION.
The electrical installation of the mixer must conform to the local electricity board
regulations. When installed in the United Kingdom the installation must be in
accordance with the current edition of the IEE Regulations for electrical equipment in
buildings and must conform to the requirements of the Electricity at work act.
A competent person must carry out the electrical installation.
The technical data shown in Table 1, page 24 details the electrical requirements for the mixer.
Ensure that the electrical power supply agrees with the machine specification prior to connection.
The mixer is equipped with a three-wire power supply cord ready for installation of an appropriate
grounding-type attachment plug. The plug and its mating receptacle must be properly grounded.
Contact an electrician. Provide proper fuse or circuit breaker protection.