.A complete Parts List is available at www.HobartWelders.com
OM-925 Page 17
5-6. Selecting A Location And Connecting Input Power
1 Rating Label
2 Grounded Receptacle
A 115 volt, 20 ampere individual branch
circuit protected by time-delay fuses or
circuit breaker is required.
3 Plug From Unit
Select extension cord of 12 AWG for up to
50 ft (15 m) or 10 AWG for 50 up to 100 ft
(30 m).
!Special installation may be
required where gasoline or volatile
liquids are present see NEC
Article 511 or CEC Section 20.
3
803 712-C
!Do not move or operate unit
where it could tip.
2
1
18 in
(460 mm)
18 in
(460 mm)