3-9. Electrical Service Guide
NOTE
All values calculated at 60% duty cycle.
50/60 Hertz Models |
|
| Without Power Factor Correction |
|
| ||||
|
|
|
|
|
|
|
|
|
|
Input Voltage | 200 | 220 | 230 | 400 | 440 | 460 |
| 520 | 575 |
|
|
|
|
|
|
|
|
|
|
Input Amperes At Rated Output | 129 | 117 | 112 | 65 | 58 | 56 |
| 49 | 45 |
|
|
|
|
|
|
|
|
|
|
Max Recommended Standard Fuse Or | 175 | 150 | 150 | 80 | 70 | 70 |
| 60 | 60 |
Circuit Breaker Rating In Amperes |
| ||||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Min Input Conductor Size In AWG/Kcmil | 4 | 4 | 4 | 8 | 8 | 8 |
| 8 | 10 |
|
|
|
|
|
|
|
|
|
|
Max Recommended Input Conductor | 111 | 134 | 146 | 196 | 238 | 260 |
| 332 | 273 |
Length In Feet (Meters) | (34) | (41) | (45) | (60) | (72) | (79) |
| (101) | (83) |
|
|
|
|
|
|
|
|
|
|
Min Grounding Conductor Size In AWG/ | 6 | 6 | 6 | 8 | 8 | 8 |
| 10 | 10 |
Kcmil |
| ||||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Reference: 1996 National Electrical Code (NEC) |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
50/60 Hertz Models |
|
|
| With Power Factor Correction |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
Input Voltage | 200 | 220 | 230 |
| 400 | 440 | 460 |
| 520 | 575 |
|
|
|
|
|
|
|
|
|
|
|
Input Amperes At Rated Output | 98 | 89 | 85 |
| 49 | 44 | 43 |
| 37 | 34 |
|
|
|
|
|
|
|
|
|
|
|
Max Recommended Standard Fuse Or | 150 | 125 | 125 |
| 70 | 70 | 60 |
| 60 | 50 |
Circuit Breaker Rating In Amperes |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
Min Input Conductor Size In AWG/Kcmil | 4 | 4 | 4 |
| 8 | 8 | 8 |
| 10 | 10 |
|
|
|
|
|
|
|
|
|
|
|
Max Recommended Input Conductor | 117 | 141 | 154 |
| 204 | 246 | 269 |
| 230 | 281 |
Length In Feet (Meters) | (36) | (43) | (47) |
| (62) | (75) | (82) |
| (70) | (86) |
|
|
|
|
|
|
|
|
|
|
|
Min Grounding Conductor Size In AWG/ | 6 | 6 | 6 |
| 8 | 8 | 10 |
| 10 | 10 |
Kcmil |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
Reference: 1996 National Electrical Code (NEC) |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|