5-3. Adjusting Spark Gaps
4 4
3
3
2 | 1 |
Tools Needed:
0.012 in (0.305 mm)
5/32 in
YTurn Off power before adjusting spark gaps.
Open access door.
1 Tungsten End Of Point
Replace point if tungsten end dis- appears; do not clean or dress tungsten.
2 Spark Gap
Normal spark gap is 0.012 in (0.305 mm).
If adjustment is needed, proceed as follows:
3 Adjustment Screws
Loosen screws. Place gauge of proper thickness in spark gap.
4 Pressure Point
Apply slight pressure at point until gauge is held firmly in gap. Tighten screws to 12 in/lbs torque (overtigh- tening will deform plastic base). Ad- just other gap.
Reinstall access door.
Ref.