4-15. Sequence Selection Switch

(CE Nameplate Only)

1

1

1 Sequence Selection Switch

Switch controls Off, Start, Cra- ter, Start/Crater, 4t, and Spot functions. Place switch in de- sired position.

Off– Place switch in Off position when Sequence Selection func- tions are not desired.

4-16. Start Time/Spot Time Control And Start Current Control

(CE Nameplate Only)

1 Sequence Selection Switch

 

1

2

 

Place switch in Start position.

 

2 Start Time/Spot Time Control

1

Use control to select 0–15 seconds

 

of start time.

 

3 Start Current Control

 

Use start control to select a starting

 

current (3–400 amps) that is differ-

 

ent from the weld current. Note:

 

Start current can be used with or

 

without a remote control.

 

Application:

 

 

Start current can be used while

 

 

GTAW welding to assist in preheat-

 

ing cold material prior to depositing

 

filler material, or to ensure a soft

2

start. Start current can also be used

for SMAW to ensure a more consis-

tent arc strike.

3