Decode Security

This selection allows you to adjust the decode security needed while scanning. For good quality codes, choose Low to achieve fast scan speed. For codes prone to misreads, choose High. Default = Low.

Note: Increasing the security level may decrease the scan speed.

* LowLow/MediumMedium/HighHigh

Continuous Scan Mode

This programs the engine to continuously scan and decode, with the laser and motor staying on.

Note: When operating in Continuous Scan Mode, the scanner’s upper operating temperature is 104°F (40°C).

Continuous Scan Mode

Output Sequence Overview

Output Sequence Editor

This programming selection allows you to program the scanner to output data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence symbol programs the scanner to the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol.

Note: To make Output Sequence Editor selections, you’ll need to know the code I.D., code length, and character match(es) your application requires. Use the Alphanumeric symbols (inside back cover) to read these options. You must hold the trigger while reading each bar code in the sequence.

To Add an Output Sequence

1.Scan the Enter Sequence symbol (see Require Output Sequence, page 3-19).

2.Code I.D.

On the Symbology Charts on page A-1,find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover).

3.Length

Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number,

3 - 16