Alarm Action Setup (1)

ENGLISH

 

<Figure 15 > Alarm Action Setup (1) screen.

This screen allows you to set up the actions the multiplexer will take when there is an alarm condition.

Buzzer : When set to On, the multiplexer’s internal buzzer will sound during an alarm condition.

Alarm Screen : When set to On, the screen display will change to the one defined in the Alarm Screen Format menu during an alarm condition.

Network Relay : When set to On, the multiplexer sends the alarm information to an external relay box via the network during an alarm condition.

Message Latch : When set to On, an “A” displays on the screen when an alarm condition occurs. It remains on the screen until it is cleared.

19