Honeywell LYNXR-2 System Overview, Master Keypad Definitions, LIGHTS ON / LIGHTS OFF KEYS Turns

Models: LYNXR-2

1 64
Download 64 pages 47.5 Kb
Page 13
Image 13
13. LIGHTS ON / LIGHTS OFF KEYS: Turns

SYSTEM OVERVIEW

5.TEST KEY: Tests the system and alarm sounder.

6.BYPASS KEY: Removes individual protection

zones from being monitored by the system. Displays currently bypassed zones.

Used to adjust volume of voice messages.

7.CODE KEY: Allows entry of additional user codes that can be given to other system users.

8.CHIME KEY: Turns the Chime mode on and

off. When on, any entry through a protected delay or perimeter zone while the system is disarmed will cause a tone and voice descriptor to sound at the keypad.

9.INTERNAL SOUNDER: Source of alarm sounds (see "Summary of Audible Notifications" section).

10.FUNCTION KEY: Allows alternate key

functions. It is used as a “repeat” key during Clock/Calendar setting.

11. NO DELAY KEY: Used with STAY or AWAY

function to eliminate the entry delay. Alarm sounds immediately if entry is opened.

12. STATUS KEY: When pressed prior to arming,

the keypad will display all open zones, and will announce system status.

13. LIGHTS ON / LIGHTS OFF KEYS: Turns

lights or other devices on or off, if programmed by the installer.

14. AUX / SELECT KEY: Can be programmed

to either perform a predefined function or to send a preset message to a pager or a “Follow Me” system phone number.

Master Keypad Definitions

15. STAY / DELETE KEY: Arms the perimeter

burglary protection, guarding protected doors, windows and other perimeter protection points, and sounds an alarm if one is opened. Interior protection is not armed, which allows movement within your house without causing an alarm. Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires. Used to delete messages.

16. AWAY / ADD KEY: Completely arms both

perimeter and interior burglary protection for backup protection by sensing an intruder's movements through protected interior areas as well as guarding protected doors, windows, etc. Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires. Used to accept “Follow Me” phone number and Clock/ Calendar mode entries.

17. OFF / ESCAPE KEY: Disarms the burglary

portion of the system, silences alarms and audible trouble indicators, and clears alarm trouble display after the problem has been corrected. Used to exit/abort “Follow Me” phone number and Clock/Calendar mode.

18.MICROPHONE: Used to record personal messages up to 85 seconds long, and for 2 way voice and speaker phone.

19.SPEAKER: Source of audible internal warning and confirmation sounds, status announcements, as well as alarms (see "Summary of Audible Notifications").

20.RECORD: Activates the recording function to record personal messages.

21.VOLUME: Sets the volume of system announcements and status beeps.

––KEYS 0-9:Used to enter your individual security access code(s).

– 13 –

Page 13
Image 13