Honeywell Mark III manual Waterproofness DO-160D Section, Fluids Susceptibility DO-160D Section

Models: Mark III

1 59
Download 59 pages 54.22 Kb
Page 54
Image 54

Waterproofness (DO-160D Section 10.0)

Category X, Not Applicable

Fluids Susceptibility (DO-160D Section 11.0)

Category X, Not Applicable

Sand and Dust (DO-160D Section 12.0)

Category X, Not Applicable

Fungus Resistance (DO-160D Section 13.0)

Category X, Not Applicable

Salt Spray (DO-160D Section 14.0)

Category X, Not Applicable

Magnetic Effect (DO-160D Section 15.0)

Category Z, Less than 0.3m for 1 degree deflection

Power Input (DO-160D Section 16.0)

Category E (AC Power), Equipment requiring AC Power.

Category B (DC Power), Electrical systems supplied by generators/alternators with a battery. Category Z (DC Power), Electrical systems without a battery of significant capacity.

Voltage Spike (DO-160D Section 17.0)

Category A, High degree of protection against voltage spikes (For both 115 Vac and 28 Vdc Versions).

Audio Frequency Susceptibility (DO-160D Section 18.0)

Category E (AC Power), Equipment requiring AC Power.

Category Z (DC Power), Electrical systems without a battery of significant capacity.

Induced Signal Susceptibility (DO-160D Section 19.0)

Category Z

RF Susceptibility (Radiated and Conducted) (DO-160D Section 20.0)

Category RRR

Emission of RF Energy (DO-160D Section 21.0)

Category M

Lightning Indirect Effects (DO-160D Section 22.0)

Category A2E2, Equipment and interconnect wiring installed in a moderately exposed environment

HONEYWELL Aerospace Electronic Systems

Page 54

Use or disclosure of information on this page is subject to the restrictions on the title page of this document.

Page 54
Image 54
Honeywell Mark III Waterproofness DO-160D Section, Fluids Susceptibility DO-160D Section, Sand and Dust DO-160D Section