Nominal

+27.5 Vdc

Nominal

50 Watts

Minimum

+20.5 Vdc

Maximum

100 Watts

Maximum

+32.2 Vdc

 

 

5.5.3 28 Vdc Backup Input Power Requirements

The MARK III does not require use of standby 28 Vdc Battery Backup Input Power.

5.5.4 Power Interrupt Requirements

The MARK III shall be capable of continuous operation through any power-off transient under 200 milliseconds. Non-volatile data shall be unaffected by Input Power Loss and does not depend upon a standby 28 Vdc Battery Bus, if the aircraft is so equipped.