Problem

Possible Cause

 

Remedy

 

 

 

 

 

b) Control Board

1. Defective.

1. See "II.C.5. Control Board

 

 

 

Check Procedure."

[7] All components

a) Refrigerant

1. Undercharged.

1. Check for leaks and

run, but no ice is

 

 

recharge.

produced.

 

2. Air or moisture

2. Replace drier and

 

 

 

 

trapped.

recharge.

 

b) Compressor

1. Defective valve.

1. Replace.

 

c) Hot Gas Valve

1. Continues to open in

1. Check and replace.

 

 

freeze cycle.

 

 

d) Inlet Water Valve

1. Water valve is wide

1. Check for water leaks with

 

 

open during freeze.

icemaker off.

 

 

 

 

b) Evaporator is Frozen Up

Problem

Possible Cause

 

Remedy

 

 

 

 

[1]Freeze cycle time is

a)Float Switch

1. Leads short-circuit or

1. Check and replace.

too long.

 

defective switch.

 

 

 

 

 

 

 

2. Float does not move

2. Clean or replace.

 

 

freely.

 

 

 

 

 

 

b)Inlet Water Valve

1. Diaphragm does not

1. Check for water leaks with

 

 

close.

icemaker off.

 

 

 

 

 

c) Control Board

1. Defective.

1. See "II.C.5. Control Board

 

 

 

Check Procedure."

 

 

 

 

[2]All ice formed on

a)Evaporator

1. Scaled up.

1. Clean.

evaporator does not

 

 

 

b)Water Supply Line

1. Water pressure too

1. Check and get

fall into bin in harvest

cycle.

 

low.

recommended pressure.

c) Water Filter System

1. Dirty/Restricted

1. Replace filter.

 

 

 

 

 

 

d)Inlet Water Valve

1. Dirty mesh filter or

1. Clean.

 

 

orifice.

 

 

 

 

 

 

 

2. Diaphragm does not

2. Check for water leaks with

 

 

close.

icemaker off.

 

 

 

 

 

e) Ambient and/or water

1. Too cool.

1. Increase temperature.

 

temperature.

 

 

 

 

 

 

 

f) Thermistor

1. Out of position or

1. See "V.H. Removal

 

 

loose attachment.

and Replacement of

 

 

 

Thermistor."

 

 

 

 

 

g)Control Board

1. Harvest timer is set

1. Adjust longer, referring

 

 

too short.

to "II.C.3. Controls and

 

 

 

Adjustments, c) Harvest

 

 

 

Timer."

 

 

 

 

 

 

2. Defective.

2. See "II.C.5. Control Board

 

 

 

Check Procedure."

 

 

 

 

[3]Other

a)Spray Tubes

1. Clogged.

1. Clean

 

 

 

 

 

 

2. Out of position.

2. Place in position.

 

 

 

 

 

b)Water System

1. Dirty.

1. Clean.

 

 

 

 

 

c) Refrigerant

1. Undercharged.

1. Check for leaks and

 

 

 

recharge.

 

 

 

 

28