Hoshizaki DKM-500BAH service manual Low Ice Production, Abnormal Ice

Models: DKM-500BAH

1 45
Download 45 pages 52.37 Kb
Page 29
Image 29

Problem

Possible Cause

 

Remedy

 

 

 

 

 

d)Expansion Valve

1. Bulb out of position or

1. Place in position.

 

 

loose attachment.

 

 

 

 

 

 

 

2. Defective.

2. Replace.

 

 

 

 

 

e)Hot Gas Valve

1. Coil winding opened.

1. Replace.

 

 

 

 

 

 

2. Plunger does not

2. Replace.

 

 

move.

 

 

 

 

 

 

 

3. Wiring to hot gas

3. Check for loose

 

 

valve.

connection or open, and

 

 

 

replace.

 

 

 

 

 

f) Ice Cube Guide

1. Out of position and ice

1. Place in position.

 

 

trapped.

 

 

 

 

 

 

g)Water Supply Line

1. Too small; requires

1. Increase water line size.

 

 

3/8" OD line dedicated

 

 

 

per machine.

 

 

 

 

 

 

h)Water Filter

1. Flow rate too small.

1. Replace with filter that has

 

 

 

larger flow rate.

c) Low Ice Production

 

 

 

 

 

 

Problem

Possible Cause

 

Remedy

 

 

 

 

[1]Freeze cycle time is

a) See chart 1. a) [3] and check dirty air filter or condenser, ambient or water

long.

temperature, water pressure, and refrigerant charge.

 

 

 

 

 

b) See chart 1. b) [1] and check float switch, inlet water valve and control board.

 

 

 

 

 

c) Check pump, hot gas valve, expansion valve, refrigeration check valve, and

 

compressor.

 

 

 

 

 

 

[2]Harvest cycle time is

a) See chart 1. b) [2] and check control board, thermistor, evaporator, ambient

long.

and/or water temperature, water supply line, inlet water valve, and hot gas

 

valve.

 

 

 

 

 

 

d) Abnormal Ice

 

 

 

 

 

 

 

Problem

Possible Cause

 

Remedy

 

 

 

 

[1] Small cubes.

a) Ice Cube Guide

1. Out of position.

1. Place in position.

 

 

Circulated water falls

 

 

 

into bin.

 

 

 

 

 

 

b) See chart 1. a) [5] and check water supply line, inlet water valve, water system,

 

pump motor, and control board.

 

 

 

 

 

 

c) Drain Valve

1. Dirty.

1. Clean.

 

 

 

 

[2] Cloudy or irregular

a) See chart 1. b) [1] and 1. b) [3], and check float switch, inlet water valve, control

cubes.

board, spray tubes, water system, refrigerant charge, and expansion valve.

 

 

 

 

 

b) Spray Guide

1. Dirty.

1. Clean.

 

c) Water Quality

1. High hardness or

1. Install a water softener or

 

 

contains impurities.

filter.

 

 

 

 

29

Page 29
Image 29
Hoshizaki DKM-500BAH service manual Low Ice Production, Abnormal Ice