49
6. KM-1601SRH with URC-21F (remote air-cooled) (auxiliary codes: some S-1; S-2 and
later)
This data applies to units with a 15 l/min or 11 l/min water valve. The 15 l/min water valve is part number 3U0111-01 and has J248-030 stamped on the side of the valve facing the rear of the unit. The 11 l/min water valve is either part number 4A1176-04 or 4A5251-04
and has the part number stamped on the side of the valve facing the front of the unit.
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specications and design without prior
notice.
70/21 1564 709 1547 702 1468 666
80/27 1551 703 1524 691 1415 642
90/32 1547 702 1505 683 1407 638
lbs./day kg./da
y
100/38 1512 686 1482 672 1317 597
70/21
80/27
90/32
watts 100/38
70/21 785 2.97 665 2.52 583 2.21
80/27 694 2.63 507 1.92 471 1.78
90/32 665 2.52 375 1.42 318 1.20
gal./day m
3
/day 100/38 519 1.97 361 1.37 266 1.01
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 213 15.0 226 15.9 245 17.2
80/27 223 15.7 243 17.1 263 18.5
90/32 226 15.9 257 18.1 277 19.5
PSIG kg/cm
2
G100/38 230 16.2 262 18.4 296 20.8
70/21 40 2.8 41 2.9 44 3.1
80/27 41 2.9 43 3.1 47 3.3
90/32 41 2.9 45 3.2 48 3.4
PSIG kg/cm
2
G100/38 42 3.0 46 3.2 51 3.6
CONDENSER VOLUME 441 CU. IN (URC-21F)
TOTAL HEAT OF REJECTION FROM CONDENSER 22,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR 3,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
4.6 2.2
29
25
26
28
2.0
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
4.2
3.4
27
29
30
32
2684
2725
2752
28002650
2636
2671
2700
2712
2610
2630
2636
24
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC) 50/10 70/21 90/32
25
25
27
2.3
5.6
3.6
4.6
3.4
2.4
4.8