15
10. KM-1601SRH3 with URC-22F (remote air-cooled) (auxiliary codes: S-2 and later)This data applies to units with an 11 l/min water valve. The 11 l/min water valve is either part number 4A1176-04 or 4A5251-04 and has the part number stamped on the side of
the valve facing the front of the unit.
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 208-230/60/3
AMPERAGE 7.9 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY 20 A
MAXIMUM FUSE SIZE 20 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *1530 (694) 1521 (690) 1414 (641)
Reference without *marks 80 1523 (691) 1508 (684) 1349 (612)
90 1521 (690) *1498 (679) 1359 (616)
100 1468 (666) 1465 (665) 1231 (558)
SHAPE OF ICE Crescent Cube
ICE PRODUCTION PER CYCLE 32.1 lbs. (14.6 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 2780(4.46) 2490(3.90)
WATER gal./24HR (gal./100 lbs.) 348(23.2) 704(46.0)
CEC/CEE TIER LEVEL 2
ENERGY STAR YES
EXTERIOR DIMENSIONS (WxDxH) 48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT
- CONDENSATE DRAIN 3/8" OD Tube
CUBE CONTROL SYSTEM Float Switch
HARVESTING CONTROL SYSTEM Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL Timer Controlled. Overflow Pipe
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model CS18K6E-TF5
CONDENSER Air-Cooled Remote, Condenser Unit URC-22F
EVAPORATOR Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-22F
REFRIGERANT CHARGE R404A, 22 lb. 14.8 oz. (10400g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 7 lb. 11.5 oz.)
DESIGN PRESSURE High 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch
ACCESSORIES -SUPPLIED N/A
-REQUIRED Ice Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONS VOLTAGE RANGE 187 - 253 V
AMBIENT TEMP. 45 -100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG