47
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specications and design without prior
notice.
4. KM-1601SWH3 (water-cooled)
70/21 1555 705 1558 707 1466 665
80/27 1557 706 1562 708 1417 643
90/32 1558 707 1565 710 1440 653
lbs./day kg./da
y
100/38 1507 684 1536 697 1326 601
70/21
80/27
90/32
watts 100/38
70/21 1714 6.49 1779 6.73 2186 8.28
80/27 1764 6.68 1866 7.06 2449 9.27
90/32 1779 6.73 1937 7.33 2455 9.29
gal./day m
3
/day 100/38 2013 7.62 2059 7.79 2930 11.09
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 239 16.8 241 16.9 257 18.1
80/27 240 16.9 244 17.1 268 18.8
90/32 241 16.9 246 17.3 267 18.8
PSIG kg/cm
2
G100/38 249 17.5 251 17.6 287 20.2
70/21 41 2.9 42 3.0 45 3.2
80/27 42 2.9 44 3.1 47 3.3
90/32 42 3.0 45 3.2 48 3.4
PSIG kg/cm
2
G100/38 43 3.0 46 3.2 51 3.6
TOTAL HEAT OF REJECTION FROM COMPRESSOR 3,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER 111 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE less than 10 PSIG
24
24
25
2.4
6.0
3.8
4.9
3.6
2.4
5.2
24
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC) 50/10 70/21 90/32
28
30
2303
2305
2351
2390
2395
2270
2297
2305
26
24
25
26
2332
2367
2411
2430
26
27
HARVEST CYCLE TIME
HEAD PRESSURE
4.4
3.6
4.9 2.2
2.0
TOTAL HEAT OF REJECTION FROM CONDENSER 23,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
SUCTION PRESSURE