50
7. KM-1601SRH with URC-22F (remote air-cooled) (auxiliary codes: S-2 and later)This data applies to units with an 11 l/min water valve. The 11 l/min water valve is either part number 4A1176-04 or 4A5251-04 and has the part number stamped on the side of
the valve facing the front of the unit.
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specications and design without prior
notice.
70/21 1531 694 1519 689 1426 647
80/27 1522 690 1503 682 1368 620
90/32 1519 689 1490 676 1371 622
lbs./day kg./da
y
100/38 1475 669 1462 663 1261 572
70/21
80/27
90/32
watts 100/38
70/21 755 2.86 637 2.41 555 2.10
80/27 665 2.52 481 1.82 444 1.68
90/32 637 2.41 352 1.33 294 1.11
gal./day m3/day 100/38 493 1.87 338 1.28 241 0.91
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 207 14.5 220 15.5 240 16.9
80/27 217 15.2 237 16.7 258 18.1
90/32 220 15.5 252 17.7 273 19.2
PSIG kg/cm2G100/38 224 15.8 257 18.1 292 20.5
70/21 40 2.8 42 2.9 44 3.1
80/27 41 2.9 44 3.1 47 3.3
90/32 42 2.9 46 3.2 49 3.4
PSIG kg/cm2G100/38 42 3.0 46 3.3 51 3.6
CONDENSER VOLUME 214 CU. IN (URC-22F)
26
26
28
2.5
5.5
3.6
4.6
3.5
2.6
4.8
25
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC) 50/10 70/21 90/32
2606
2604
2662
2710
2719
2560
2593
2604
28
30
31
34
2645
2693
2746
2780
29
26
27
29
2.0
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
4.1
3.4
4.6 2.3
TOTAL HEAT OF REJECTION FROM CONDENSER 21,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]