Hoshizaki KM-630MRF Removal And Replacement Of Water Valve, Removal And Replacement Of Pump Motor

Models: KM-630MRF KM-630MWF KM-630MAF

1 61
Download 61 pages 5.91 Kb
Page 53
Image 53

6)Install the new Fan Motor, and replace the removed parts in the reverse order of which they were removed.

7)Replace the panels in their correct positions.

8)Replace the Junction Box Cover in its correct position (Remote Air-cooled model).

9)Turn on the power supply.

13.REMOVAL AND REPLACEMENT OF WATER VALVE

1)Turn off the power supply.

2)Close the Water Supply Line Shut-off Valve.

3)Remove the Front Panel.

4)Remove the Valve Outlet Tubing by releasing the Clamp.

5)Remove the Bracket from the unit.

6)Remove the Fitting Nut and Water Valve.

7)Disconnect the Terminals from the Water Valve.

8)Install the new Water Valve, and replace the removed parts in the reverse order of which they were removed.

9)Open the Water Supply Line Shut-off Valve.

10)Turn on the power supply.

11)Check for leaks.

12)Replace the Front Panel in its correct position.

14. REMOVAL AND REPLACEMENT OF PUMP MOTOR

1)Turn off the power supply.

2)Remove the Front Panel.

53

Page 53
Image 53
Hoshizaki KM-630MRF, KM-630MAF, KM-630MWF Removal And Replacement Of Water Valve, Removal And Replacement Of Pump Motor