2. EVAPORATOR IS FROZEN UP

PROBLEM

POSSIBLE CAUSE

 

REMEDY

[1] Freeze cycle

a) Float Switch

1.

Leads short-circuit or

1.

Check and replace.

time is too

 

 

 

defective switch.

 

 

 

 

long.

 

 

2.

Float does not move freely.

2.

Clean or replace.

 

b) Water Solenoid

1.

Diaphragm does not close.

1.

Check for water leaks

 

Valve

 

 

 

with icemaker off.

 

c) Controller Board

1.

Defective.

1.

See “II.2[e] CHECKING

 

 

 

 

 

 

CONTROLLER BOARD.”

[2] All ice formed

a) Evaporator

1.

Scaled up.

1.

Clean.

 

 

on Evaporator

b) Water Supply Line

1.

Water pressure too low.

1.

Check and get

does not fall

 

 

 

 

 

recommended pressure.

into bin in

c) Water Solenoid

1.

Dirty mesh filter or orifice.

1.

Clean.

harvest cycle.

Valve

2.

Diaphragm does not close.

2.

Check for water leaks

 

 

 

 

 

 

with icemaker off.

 

d) Ambient and/or

1.

Too cool.

1.

Increase temperature.

 

water temperature

 

 

 

 

 

 

 

e) Line Valve

1.

Continues to open in

1.

Check operation in

 

 

 

 

harvest cycle.

 

harvest cycle and replace.

 

f) Thermistor

1.

Out of position or loose

1. See “V. 11. REMOVAL

 

 

 

 

attachment..

 

AND REPLACEMENT OF

 

 

 

 

 

 

THERMISTOR.”

 

g) Controller Board

1.

Defrost Timer is set too

1.

Adjust longer, referring

 

 

 

 

 

short.

 

to “II. 2. [d] CONTROLS

 

 

 

 

 

 

AND ADJUSTMENT, 2)

 

 

 

 

 

 

Defrost Timer.”

 

 

 

 

 

 

 

 

 

 

2. Defective.

2.

See “II. 2.[e] CHECKING

 

 

 

 

 

 

CONTROLLER BOARD.”

[3] Others

a) Spray Tubes

1. Clogged.

1. Clean.

 

 

 

2.

Out of position.

2.

Place in position.

 

 

b) Water System

1.

Dirty.

1.

Clean.

 

c) Refrigerant

1. Undercharged.

1.

Check for leaks and

 

 

 

 

 

 

recharge.

 

d) Expansion Valve

1.

Bulb out of position or

1.

Place in position.

 

 

 

 

loose attachment.

 

 

 

 

 

 

 

2. Defective.

2.

Replace.

 

e) Hot Gas Solenoid

1. Coil winding opened.

1. Replace.

 

Valve

 

2.

Plunger does not move.

2. Replace.

 

 

 

3.

Wiring to Hot Gas Valve.

3.

Check for loose

 

 

 

 

 

 

connection or open, and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

 

3. LOW ICE PRODUCTION

PROBLEM

POSSIBLE CAUSE

REMEDY

[1]

Freeze cycle

a) See chart 1 - [3], and check dirty Air Filter or Condenser, ambient or water

 

time is long.

temperature, water pressure, Water Regulator or refrigerant charge.

 

 

b) See chart 2 - [1], and check Float Switch, Water Solenoid Valve or Controller

 

 

Board.

 

[2]

Harvest cycle

a) See chart 2 - [2], and check Controller Board, Thermistor, Evaporator, ambient

 

time is long

and/or water temperature, water supply line, Water Solenoid Valve or Line Valve.

 

 

 

 

38

Page 38
Image 38
Hoshizaki KM-630MRF, KM-630MAF, KM-630MWF service manual Evaporator is Frozen UP, LOW ICE Production

KM-630MRF, KM-630MWF, KM-630MAF specifications

The Hoshizaki KM-630MWF, KM-630MAF, and KM-630MRF are advanced commercial ice machines designed to meet the needs of various businesses, including restaurants, bars, and cafes. Renowned for their efficiency, durability, and performance, these models showcase Hoshizaki's dedication to innovation in the foodservice industry.

One of the primary features of the Hoshizaki KM-630 series is the production of crescent-shaped ice. This type of ice is not only aesthetically pleasing but also known for its slow melting properties, making it ideal for keeping beverages cold without diluting them quickly. With a production capacity of up to 617 pounds of ice per day, these machines are built to handle high-demand scenarios efficiently.

The KM-630MWF model is equipped with a water-cooled condenser, making it suitable for environments where air-cooled units might face challenges due to high ambient temperatures. In contrast, the KM-630MAF features an air-cooled condenser which is advantageous for businesses looking to reduce water usage. The KM-630MRF variant utilizes a remote-cooled option, offering flexibility in installation and reducing heat and noise in the kitchen areas.

All three models are built with superior quality stainless steel, ensuring durability and resistance to rust and corrosion. They are designed to be easy to clean, featuring a smooth surface that minimizes dirt and bacteria buildup. Furthermore, Hoshizaki incorporates their advanced EverCheck alert system, providing operators with real-time performance notifications and ensuring reliable operation.

Energy efficiency is a crucial characteristic of the KM-630 series. These machines are designed to comply with industry standards, significantly reducing energy consumption and operating costs. Their highly efficient refrigeration system not only enhances ice production but also extends the lifespan of the machine.

In terms of ease of use, Hoshizaki has designed the KM-630 series to feature a user-friendly control panel. This panel allows for straightforward monitoring and modification of operations, ensuring operators can manage the machine effectively.

Overall, the Hoshizaki KM-630MWF, KM-630MAF, and KM-630MRF ice machines represent a blend of advanced technology, energy efficiency, and robust construction, making them an ideal choice for businesses that demand high-quality ice production. With their innovative features, these machines are poised to elevate the service capabilities of any establishment.