2.
WIRING DIAGRAMS
[a]
KM-630MAF
and
KM-630MWF
Note: Pressure Switch
Cut-out
412
±
21
PSIG
0
Cut-in
327
± 21
PSIG
28
Page 27
Page 29
Page 28
Image 28
Page 27
Page 29
Contents
SERVICE MANUAL
KM-630MAF KM-630MWF KM-630MRF
HOSHIZAKI MODULAR CRESCENT CUBER
MODEL
HOSHIZAKI AMERICA, INC 618 Highway 74 South Peachtree City, GA
CONTENTS
PAGE
V. REMOVAL AND REPLACEMENT OF COMPONENTS
SERVICE FOR REFRIGERANT LINES
a REFRIGERANT RECOVERY
REMOVAL AND REPLACEMENT OF COMPRESSOR
I. SPECIFICATIONS 1. KM-630MAF
2. KM-630MWF
3. KM-630MRF
4. CONDENSER UNIT URC-6F
SPECIFICATIONS
MODEL URC-6F
II. GENERAL INFORMATION 1. CONSTRUCTION
a KM-630MAF
b KM-630MWF
c KM-630MRF
Features of Control Products “E” Controller Board
2. CONTROLLER BOARD
a SOLID-STATE CONTROL
b CONTROLLER BOARD
2 Defrost Timer
3 High Temperature Safety - 127 ± 7F
4 Low Water Safety
6 LED Lights and Audible Alarm Safeties
1 beep every 3 sec. = High Evaporator Temperature 127 F
1 Minute Fill Cycle
Harvest Cycle
Freeze Cycle
Control Products HOS-001A Board
c SEQUENCE 1st Cycle
IMPORTANT Water Valve opening is limited to 6 minutes
2nd Cycle and after with pump drain
IMPORTANT Water Valve opening is limited to 6 minutes
2nd Cycle and after with no pump drain
IMPORTANT Water Valve opening is limited to 6 minutes
d CONTROLS AND ADJUSTMENTS
Temperature F
Check a thermistor for resistance by using the following procedures
i Disconnect the connector K3 on the board
2 Defrost Timer
3 Drain Timer
The Drain Timer is factory-adjusted, and no adjustment is required
SETTING
Dip Switch
e CHECKING THE CONTROLLER BOARD
At this point, the unit should start the defrost cycle
After the 1 minute water supply cycle, the defrost cycle starts
III. TECHNICAL INFORMATION
1. WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM-630MAF
b KM-630MWF
c KM-630MRF
2. WIRING DIAGRAMS
a KM-630MAF and KM-630MWF
b KM-630MRF
U1GMA0179608
If Float Sw. is OFF
3. TIMING CHART
From Defrost Cycle To Defrost Cycle
To Freeze Cycle From Freeze Cycle
4. PERFORMANCE DATA a KM-630MAF
b KM-630MWF
c KM-630MRF
IV. SERVICE DIAGNOSIS 1. NO ICE PRODUCTION
PROBLEM
POSSIBLE CAUSE
REMEDY
POSSIBLE CAUSE
PROBLEM
REMEDY
POSSIBLE CAUSE
PROBLEM
REMEDY
2. EVAPORATOR IS FROZEN UP
3. LOW ICE PRODUCTION
PROBLEM
PROBLEM
5. OTHERS
4. ABNORMAL ICE
Solenoid Valve, water system
V. REMOVAL AND REPLACEMENT OF COMPONENTS
1. SERVICE FOR REFRIGERANT LINES
a REFRIGERANT RECOVERY
b EVACUATION AND RECHARGE R-404A
2. BRAZING DANGER
3. REMOVAL AND REPLACEMENT OF COMPRESSOR IMPORTANT
18 Turn on the power supply
17 Replace the panels in their correct positions
5. REMOVAL AND REPLACEMENT OF EXPANSION VALVE
4. REMOVAL AND REPLACEMENT OF DRIER
KM9311
6. REMOVAL AND REPLACEMENT OF HOT GAS VALVE AND LINE VALVE
1 Turn off the power supply 2 Remove the panels
3 Recover the refrigerant and store it in an approved container
5 Disconnect the Hot Gas Valve or Line Valve using brazing equipment
6 Install the new valve
7. REMOVAL AND REPLACEMENT OF EVAPORATOR IMPORTANT
Page
9. ADJUSTMENT OF WATER REGULATING VALVE - WATER-COOLED MODEL ONLY
Page
11. REMOVAL AND REPLACEMENT OF THERMISTOR CAUTION
Thermistor Lead
Cable Tie
Foam Insulation
12. REMOVAL AND REPLACEMENT OF FAN MOTOR
Min. 4-3/4 Liquid Bypass Flow
13. REMOVAL AND REPLACEMENT OF WATER VALVE
14. REMOVAL AND REPLACEMENT OF PUMP MOTOR
15. REMOVAL AND REPLACEMENT OF SPRAY TUBES
VI. MAINTENANCE AND CLEANING INSTRUCTIONS
1. PREPARING THE ICEMAKER FOR LONG STORAGE
2 Move the Control Switch, on the Control Box, to the “OFF” position
7 Move the Control Switch to the “ICE” position
3 Drain the Potable Water Tank 1 Turn off the power supply
2 Move the Control Switch to the “OFF” position
2. CLEANING
CLOSED POSITION OPEN POSITION
a CLEANING PROCEDURE
20 Turn on the power supply to fill the Water Tank with water
21 Turn off the power supply after 3 minutes
22 Remove the Front Panel, and fully open the Cleaning Valve
23 Move the Control Switch to the “Wash” position
b SANITIZING PROCEDURE - Following Cleaning Procedure
3. MAINTENANCE