Hoshizaki KM-630MAF Timing Chart, If Float Sw. is OFF, From Defrost Cycle To Defrost Cycle

Models: KM-630MRF KM-630MWF KM-630MAF

1 61
Download 61 pages 5.91 Kb
Page 30
Image 30
3. TIMING CHART

3. TIMING CHART

When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermistor Temp. exceeds t1.

*

*

If Float Sw. is OFF

Hi Temp Mid Temp Lo Temp Too Lo Temp

Time Up (60 sec)

Control

Sw. in

ICE

Bin Thermo- stat ON

Pressure

Sw. ON

Overheat

Protect

Reset

Min.

Max.

Max.

2 min

6 min

6 min

Max. 20 min

From Defrost Cycle

To Defrost Cycle

Normal Too Hi Temp Lo Water

Max. Min.

60 min 5 min

*NOTE: The icemaker does not complete a defrost cycle in the first 2 or 3 minutes. See “II. 2. [d] CONTROLS AND ADJUSTMENTS.”

30

Page 30
Image 30
Hoshizaki KM-630MAF, KM-630MWF, KM-630MRF Timing Chart, If Float Sw. is OFF, From Defrost Cycle To Defrost Cycle