Control panel message

Description

Recommended action

 

 

 

921-Device in PCI Express slot failed to

There is an incompatibility/problem with this

Try rebooting the system. If the error

initialize

device and the system or PCI Express Link

reoccurs, the device may not work with this

 

could not be retrained to an x1.

system

 

 

 

 

1720-SMART Hard Drive Detects Imminent

Hard drive is about to fail. (Some hard

1.

Determine if hard drive is giving correct

Failure

drives have a hard drive firmware patch that

 

error message. Enter Computer Setup

 

will fix an erroneous error message.)

 

and run the Drive Protection System

 

 

 

test under Storage > DPS Self-test.

 

 

2.

Apply hard drive firmware patch

 

 

 

if applicable. (Available at

 

 

 

http://www.hp.com/support.)

 

 

3.

Back up contents and replace hard

 

 

 

drive.

 

 

 

 

1801-Microcode Patch Error

Processor is not supported by ROM BIOS.

1.

Upgrade BIOS to proper version.

 

 

2.

Change the processor.

 

 

 

1805-Ambient Temperature Previously Over

This system was placed in a low power

Make sure the system meets the HP

Limit

state to prevent damage due to excessive

enclosure guidelines as listed in the

 

environmental temperature.

QuickSpecs, including the following:

 

 

1.

Clean the air vents on the front, back,

 

 

 

or any other vented side of the

 

 

 

computer.

 

 

2.

Ensure that there is a 10.2 cm (4 in)

 

 

 

clearance on all vented sides of the

 

 

 

computer to permit the required airflow.

 

 

3.

Ensure that computers are not so near

 

 

 

each other that they are subject to

 

 

 

each other's re-circulated or preheated

 

 

 

air.

 

 

 

 

2200-PMM Allocation Error during MEBx

Memory error during POST execution of the

1.

Reboot the computer.

Download

Management Engine (ME) BIOS Extensions

2.

Unplug the power cord, re-seat the

 

option ROM.

 

 

 

memory modules, and reboot the

 

 

 

computer.

 

 

3.

If the memory configuration was

 

 

 

recently changed, unplug the

 

 

 

computer, restore the original memory

 

 

 

configuration, and reboot the

 

 

 

computer.

 

 

4.

If the error persists, replace the system

 

 

 

board.

 

 

 

 

130 Appendix D POST Error Messages

Page 137
Image 137