HP 13-a010nr x360 d. Remove the webcam/microphone module, Removal and replacement procedures

Models: 13-a019wm x360 13-a072nr x360 13-a013cl x360

1 86
Download 86 pages 20.56 Kb
Page 60
Image 60
d.Remove the webcam/microphone module.

c.Disconnect the webcam/microphone module cable (2) from the webcam/ microphone module.

d.Remove the webcam/microphone module.

The webcam/microphone module is available using spare part number 768040-001.

13.If it is necessary to replace the display panel cable:

CAUTION: Before turning the display panel upside down, make sure the work surface is clear of tools, screws, and any other foreign objects. Failure to follow this caution can result in damage to the display panel.

a.Turn the display panel upside down with the bottom toward you.

b.Release the adhesive strip (1) that secures the display panel cable connector to the display panel.

c.Disconnect the display panel cable (2) from the display panel.

d.Release the display panel cable from the retention clips (3) and channel built into the display back cover.

52

Chapter 5 Removal and replacement procedures

Page 60
Image 60
HP 13-a010nr x360 manual d. Remove the webcam/microphone module, If it is necessary to replace the display panel cable