HP 280 G1 manual Check that the unit is plugged into a working, AC outlet

Models: 280 G1

1 136
Download 136 pages 38.85 Kb
Page 110
Image 110

Activity

Beeps

Possible cause

Recommended action

 

 

 

 

 

 

 

 

1.

Check that the unit is plugged into a working

 

 

 

 

AC outlet.

 

 

 

2.

Open hood and check that the power button

 

 

 

 

harness is properly connected to the system

 

 

 

 

board.

 

 

 

3.

Check that both power supply cables are

 

 

 

 

properly connected to the system board.

 

 

 

4.

Check to see if the 5V_aux light on the system

 

 

 

 

board is turned on. If it is turned on, then

 

 

 

 

replace the power button harness. If the

 

 

 

 

problem persists, replace the system board.

 

 

 

5.

If the 5V_aux light on the system board is not

 

 

 

 

turned on, remove the expansion cards one at

a time until the 5V_aux light on the system board turns on. It the problem persists, replace the power supply.

102 Chapter 8 POST error messages