Removal and replacement procedures

The thermal material must be thoroughly cleaned from the surfaces of the fan/heat sink assembly and the system board each time the fan/heat sink assembly is removed:

Thermal paste is used on the processor 1 and the heat sink section 2 that services it.

Thermal pads are used on the Northbridge chip 3 and the heat sink section 4 that services it.

Thermal pads are used on the other system board components 5 and sections of the heat sink 6 that service them.

Replacement thermal material is included with all system board, fan/heat sink assembly, and processor spare part kits.

Reverse this procedure to install the fan/heat sink assembly.

4–50

Page 98
Image 98
HP CQ36-106TX, CQ36-108TX, CQ36-109TX, CQ36-104TX, CQ36-105TX, CQ36-103TX manual Removal and replacement procedures