Parameters

<seconds>

Specifies the maximum time period to wait

 

before performing the specified client action.

 

The default value is 300 seconds.

 

 

Example rcu /monitor /monitoridlewait 10 /monitormaxwait 300 /mirror c:\build server1 build1

Logging Options

The following section describes the logging CLI commands. It contains the following

CLI commands:

‹“/logfile,” next

‹“/logfilemax” on page 30

‹“/logfilename” on page 31

‹“/logfilenum” on page 31

‹“/quiet” on page 31

‹“/verbose” on page 31

 

/logfile

Description

Writes logs to a file. The default file name is rcu.log.txt.

Syntax

/logfile

Parameters

None

Example

rcu /server /logfile

/logfilemax

Description

Specifies the maximum log file size in bytes. The default value is 8777 bytes.

Syntax

/logfilemax <num>

 

Parameters

 

 

 

 

 

 

<num>

Specifies the maximum size of the log file in

 

 

bytes.

Example

 

rcu /server /logfile /logfilemax 15000

30

3 - THE HP EFS RCU COMMANDS

Page 32
Image 32
HP Enterprise File Services WAN Accelerator manual Logging Options, Logfilemax