Hickory Industries, Inc.
II.Operating Instructions
1.0 Start Up
a.Switch the exhaust hood to on.
b.Open the gas cock at the rear of the machine.
c.Turn the knob on the manifold valve to the "pilot" position.
d.While pressing the "flow index" button down, place a match, or other type of ignition method, to the pilot burner until it is lit. Keep the knob pressed down for at least 40- 60 seconds so that the thermocouple tip warms up and the pilot flame remains lit.
e.Release the knob. The pilot flame should stay on.
f.Repeat the procedure for the other burners.
g.Turn the manifold valve knob to the desired setting ("on" must be lined up with the "flow index" button for high flame or maximum heat). The pipe burner should now light up.
h.Allow the unit to
i.When ready to load the spits with product, turn the light and the motor switches to the on position.
2.0Shut Down
a.Turn the manifold valve knobs to the "off" position if all flames are to be shut off. If the pilot light is to remain lit and only the pipe burners are to be shut off, turn the manifold valve knobs to the "pilot" position. Note that to turn the knobs to the "off" position, one must pull out on the locking mechanism on the knobs and then turn the valve to the off position.
b.After all of the loaded spits have been removed, turn the motor and lights off.
c.Close the gas cock at the rear of the machine if the pilot flames are also shut off.
d.Turn off the exhaust hood.
WARNING! Do not clean the machine or glass while these are hot! Everything should be cooled down before cleaning.
4900 Westside Avenue, North Bergen, New Jersey 07047 | N/45 Series Manual12/00 |
Tel: [201] | Page 20 of 38 |