HP Hickory Rotis N/45WDG manual Maintenance Procedures for Continuous Cook Rotisseries

Models: Hickory Rotis 45WDG PLUS Hickory Rotis N/45WDG

1 38
Download 38 pages 30.42 Kb
Page 36
Image 36

Hickory Industries, Inc.

10.Maintenance Procedures for Continuous Cook Rotisseries

The most effective maintenance procedure that you can perform will be the daily cleaning procedure.

Monthly:

To ensure that the burner is operating efficiently, remove the ceramics and use a paper clip to clean any debris from the burner openings.

To ensure proper air/gas mixture, the venturi air inlet gap needs to be cleaned. This can be done using a paring knife or business card. Refer to the operating manual.

Every 6 Months:

To ensure that the shaft worm nylon gears properly mesh with the spit gears, place a spit into each spit position with the motor running. If the gears jump or do not align properly, adjust them using the allen wrench provided – DO NOT OVER TIGHTEN THE SCREWS.

Every 12 Months:

Inspect the spit plates and verify that the brass oil lite bushings are in place for each spit position. Replace any worn or missing bushings.

Remove the glass and inspect for scratches and or chips. If any are found replace the glass as soon as possible. Also, inspect the glass trolleys. If they are worn, replace them.

Units with sliding side doors – the upper and lower slides needed to be greased.

4900 Westside Avenue, North Bergen, New Jersey 07047

N/45 Series Manual12/00

Tel: [201] 223-0050 Fax: [201] 223-0950

Page 36 of 38

Page 36
Image 36
HP Hickory Rotis N/45WDG, Hickory Rotis 45WDG PLUS manual Maintenance Procedures for Continuous Cook Rotisseries