Acknowledgement

[j][][Set ID][][OK/NG][Data][x]

27. Elapsed time return (Command : d l)

To read the elapsed time.

Transmission

[d][l][][Set ID][][Data][Cr]

*The data is always FF(in Hex). Acknowledgement

[l][][Set ID][][OK/NG][Data][x]

*The data means used hours. (Hexadecimal code)

28.Temperature value (Command : d n)

To read the inside temperature value.

Transmission

[d][n][][Set ID][][Data][Cr]

*The data is always FF(in Hex). Acknowledgement

[n][][Set ID][][OK/NG][Data][x]

*The data is 1 byte long in Hexadecimal.

29.Lamp fault Check (Command : d p)

To check lamp fault.

Transmission

[d][p][][Set ID][][Data][Cr]

*The data is always FF(in Hex). Acknowledgement