First Alert FA148CPSSIA manual Setting the REAL-TIME Clock, Repeat Option, Randomize

Models: FA148CPSSIA

1 40
Download 40 pages 18.24 Kb
Page 32
Image 32

REPEAT OPTION

0 - 4X

Repeat Option

0 = do not repeat

1 = repeat weekly

2 = repeat biweekly (every other week)

3 = repeat every third week

4 = repeat every fourth week Press [] to continue.

Enter the desired repeat option for this schedule.

e.g., To make a schedule that happens everyday you would select all days with a repeat count of 1. To make a schedule that runs for one week then stops, select everyday with a repeat count of 0.

RANDOMIZE

0 = N O 1 = YE S X

Randomize

0 = no

1 = yes

Press [] to continue and return to ENTER SCHED NO. prompt to program the next schedule.

(For events 01 and 11)

If selected, the scheduled start and stop times will vary within 60 minutes of the “hour” time. For example, if a schedule is set to start at 6:15pm, it will do so the first time 6:15pm arrives, but on subsequent days it will start anytime between 6:00 and 6:59 p.m.

NOTE: Do not use the random option if the start and stop times are within the same “hour” setting, otherwise unpredictable results may occur (e.g., the randomized stop time may occur before the start time).

AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS

Applies to an AVS system using an ECP connection to the control.

1.Install the AVS module according to its instructions.

2.Use one of the control’s AVS Quick Program commands as follows (see Quick Program Command Results below for results of each command):

installer code + [#] + 0 + 3: enable AVS operation without panel sounds on the AVST speaker

installer code + [#] + 0 + 4: enable AVS operation and enable panel sounds on the AVST speaker

3.Use data field 55 Dynamic Signaling Priority to select the desired reporting paths (phone line and/or GSMV) and path for AAV communication.

4.To undo the Quick Command programming, use the following commands:

installer code + [#] + 0 + 5: remove all options that were set if [#] + 03 quick command was performed

installer code + [#] + 0 + 6: remove all options that were set if [#] + 04 quick command was performed

Quick Program Command Results

When either the #03 or #04 Quick Program command is used, the following are automatically programmed and no longer available for other control panel purposes.

Pre-Programmed

#03 Command

 

#04 Command

Output Function No.

FA148CP

FA168CPS

FA148CP

FA168CPS

(80 mode)

22 (zone type 60, relay 07)

46 (zone type 60, relay 15)

Same as #03 plus:

Same as #03 plus:

 

23 (zone type 61, relay 08)

47 (zone type 61, relay 16)

17

(zone type 14, relay 05)

41

(zone type 14, relay 13)

 

24 (zone type 62, relay 08)

48 (zone type 62, relay 16)

18

(zone type 22, relay 05)

42

(zone type 22, relay 13)

 

 

 

19

(zone type 39, relay 06)

43

(zone type 39, relay 14)

 

 

 

20

(zone type 33, relay 06)

44

(zone type 33, relay 14)

 

 

 

21

(zone type 22, relay 06)

45

(zone type 22, relay 14

Output Relay No.

07 (addr 08, relay pos 2)

15 (addr 11, relay pos 2)

Same as #03 plus:

Same as #03 plus:

(79 mode)

08 (addr 08, relay pos 1)

16 (addr 11, relay pos 1)

05

(addr 08, relay pos 4)

13

(addr 11, relay pos 4)

 

 

 

06

(addr 08, relay pos 3)

14

(addr 11, relay pos 3)

Protection Zone

4229 zn 24 (zt 81, addr 08)

4229 zn 48 (zt 81, addr 11)

Same as #03 command

Same as #03 command

(56/58 mode)

 

 

 

 

 

 

Device Address

address 08 (AVS module)

address 11 (AVS module)

Same as #03 command

Same as #03 command

Data Field 91

AAV enabled

AAV enabled

 

AAV enabled

 

AAV enabled

SETTING THE REAL-TIME CLOCK

IMPORTANT: The Real-Time Clock must be set before the end of the installation.

NOTE: All partitions must be disarmed before the date/time can be set.

1.Master Code + [#] + [6] [3]

2.Press [] when the time/date is displayed.

A cursor appears under the first digit of the hour.

To move cursor ahead, press []. To go back, press [#].

Enter the 2-digit hour setting.

Enter the 2-digit minute setting.

Press [1] for PM or [2] for AM.

Enter the last two digits of the current year.

Enter the 2-digit month setting.

Enter the 2-digit day setting.

3.To exit, press [] when cursor is at the last digit, or wait 30 seconds.

32 –

Page 32
Image 32
First Alert FA148CPSSIA manual Setting the REAL-TIME Clock, Repeat Option, Randomize, Quick Program Command Results

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.