KEYPAD OPTIONS *190-*199

KEYPAD OPTIONS *190-*199

To enable keypads:

1.Set desired address at keypad (refer to keypad’s instructions for setting the address).

2.Use data fields *190-*196 to enable keypad addresses, assign a partition, enable sound options in field.

3.Use fields *197, *198, and *199 to turn on partition number display, exit time interval display, and select fail display mode.

4.Set keypad-related data fields as appropriate: *21 Quick Arm Enable, *23 Forced Bypass, *84 Auto STAY Arm

NOTES: 1. Options for keypad 1, address 16, are set by the factory and cannot be changed.

2.Each keypad must be assigned a unique address. Keypads programmed with the same address will give unpredictable results.

190 Keypad 2 Device Address 17

Partition/ Enable:

FA168CPS: Enter partition where:

0 = keypad disabled

1-3 = part. no. (3 = common)

FA148CP:

0 = disable

1 = enable

Sound: 0 = no suppression

1 = suppress arm/disarm and Entry/Exit beeps

2 = Suppress chime beeps only

3 = suppress arm/disarm, Entry/Exit, and chime beeps

[0] [0]

Partition/ Sound

Enable

Partion/Enable: For FA168CPS, enter the partition in which the keypad is located; for FA148CP, enter 1 to enable, or 0 to disable the keypad.

Sound: Enter the desired sound option for this keypad.

 

191

Keypad 3 Device Address 18

 

 

 

 

[0]

[0]

 

 

 

 

 

 

 

See field 190 for entries.

 

 

 

 

 

 

 

 

Part/Enable

Sound

 

 

 

 

 

 

 

Keypad 4 Device Address 19

 

 

 

 

 

 

192

 

 

 

 

[0]

 

 

 

 

 

[0]

 

 

See field 190 for entries.

 

 

 

 

 

 

 

 

Part/Enable

Sound

 

 

 

 

 

 

 

Keypad 5 Device Address 20

 

 

 

 

 

 

193

 

 

 

 

[0]

 

 

 

 

 

[0]

 

 

See field 190 for entries.

 

 

 

 

 

 

 

 

Part/Enable

Sound

 

 

 

 

 

 

 

Keypad 6 Device Address 21

 

 

 

 

 

 

194

 

 

 

 

[0]

 

 

 

 

 

[0]

 

 

See field 190 for entries.

 

 

 

 

 

 

 

 

Part/Enable

Sound

 

 

 

 

 

 

 

Keypad 7 Device Address 22

 

 

 

 

 

 

195

 

 

 

 

[0]

 

 

 

 

 

[0]

 

 

See field 190 for entries.

 

 

 

 

 

 

 

 

Part/Enable

Sound

 

 

 

 

 

 

 

Keypad 8 Device Address 23

 

 

 

 

 

 

196

 

 

 

 

[0]

 

 

 

 

 

[0]

 

 

See field 190 for entries.

 

 

 

 

 

 

 

 

Part/Enable

Sound

 

 

 

 

 

 

197

Exit Time Display Interval

 

 

 

 

 

 

 

[0]

 

 

 

0 = no display

1-5 = seconds between display refresh If enabled, keypads display the exit time remaining after arming the system, updated at the interval selected (i.e. if the exit delay is 30

seconds and “2” is selected in this field, the keypad display refreshes every 2 seconds, displaying 30, 28, 26, 24, etc.).

An interval greater than “1” may be necessary for some older keypads to allow users time to enter key presses between display updates. NOTE: If enabled and using only 2-digit fixed-word keypads (e.g., FA245RF), do not set exit delay time greater than 96 seconds. Using a longer delay time may cause end-user confusion because 2-digit display keypads cannot display times greater than “99.” If longer exit time is required by the installation, it is recommended that the Exit Time Display option be disabled (“0”).

TOUCH SCREEN DEVICE NOTE: If using more than one touch screen device (e.g., FA700KP, Symphony) with the system, leave field *197 Exit Time Display Interval set to the default value “0.” The FA700KP automatically displays remaining exit time in one-second increments.

 

198

Display Partition Number

[0]

 

 

 

 

 

 

0

= no

(FA168CPS; for Alpha Display Keypads)

 

 

 

 

1

= yes (partition no. displayed)

If selected, the partition number is displayed in the upper-left corner of

 

 

 

 

the display. This is useful when using the GOTO partition function.

199 ECP Fail Display

0 = 3-digit display

“1” + device address)

1 = 2-digit fixed-display as “91

[0]

Select “0” if using Alpha keypads and/or 3-digit Fixed-Word Display keypads. ECP faults will display “1” plus the device address (00-30) of device causing the fault (e.g., faults on device 07 display as “107”).

Select “1” if using 2-digit Fixed-Word Display keypads (e.g., certain

6128 series keypads). If selected, ECP faults for all devices will display as “91” on 2-digit displays, and “191” on 3-digit or Alpha keypads.