TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (∗59 thru ∗68, *70 thru ∗76, and ∗89): For 3+1 or 4+1 Standard Format: Enter a code in the first box:
A 0 (not #+10) in the first box disables a report. A 0 (not #+10) in the second box results in advance to the next field. For Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for
A 0 (not #+10) in the second box will eliminate the expanded message for that report. A 0 (not #+10) in both boxes will disable the report.
For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the second boxes are ignored).A 0 (not #+10) in the first box disables the report.
UL: Report codes are required in fields *61, *65, *71, *72, for UL Commercial Burglar Alarm installations.
Report codes are required in fields *60, *62, *63, *64, *70, *73, *74, *75, *76, for UL Commercial Burglar Alarm installations and required for Residential Fire Alarm installations
SYSTEM STATUS REPORT CODES (✱59–✱ 68)
∗59 |
|
| Exit Error Alarm Report Code | |||
|
|
| See above for entries. | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| [1] Always enabled. |
|
|
[0]
After arming the system, entry/exit and interior zones remaining open after exit delay expires cause an alarm sound at the keypad and external sounder (keypad also displays “EXIT ALARM”), and entry delay begins. Disarming before the end of the entry delay stops the alarm sounding and no message is sent to the central station. The keypad will display “CA”
If the system is not disarmed before entry delay expires, an “EXIT ALARM” message
An Exit Alarm condition will also result if a fault occurs in an exit or interior zone within 2 minutes following the end of the exit delay, and an “EXIT ALARM” message will be sent to the central station (except for
∗60 | Trouble Report Code |
|
|
[10] |
See above for entries.
Sent if a zone has a trouble condition.
See UL System Reporting Note above *59.
∗61 | Bypass Report Code |
|
|
[00] |
See above for entries.
Sent when a zone is manually bypassed.
See UL System Reporting Note above *59.
∗62 | AC Loss Report Code |
| See above for entries. |
[10] |
Timing of this report is random with up to a
See UL System Reporting Note above *59.
∗63 | Low Bat Report Code |
| |
[10] |
See above for entries.
Sent when the system’s backup battery has a
See UL System Reporting Note above *59
∗64 Test Report Code
See above for entries.
Periodic Test Report Scheduling Commands:
installer code +[#] + [0] + 0 = report every 24 hrs
installer code +[#] + [0] + 1 = report once per week
installer code +[#] + [0] + 2 = report every 28 days
[00] |
Sent periodically to test that the communicator and phone lines are operational.
Frequency of report is set in Scheduling mode (event 11) or by the key commands listed at left:
Each mode sets schedule 32 (FA168CPS) or schedule 08 (FA148CP) to the stated repeat option; first test report sent 12 hours after command.†
See System Reporting UL Note above *59.
†NOTE: Make sure the
∗65 | Open Report Code |
|
| [0,0,0] |
|
| |||
| See above for entries. |
|
| Common |
|
| |||
| Part. 1 Part. 2 |
Sent upon disarming the system in the selected partitions.
See UL System Reporting Note above *59.