First Alert FA148CPSSIA Menu Mode, Output Function No, Summary Screen, Activated By, Zone List

Models: FA148CPSSIA

1 40
Download 40 pages 18.24 Kb
Page 26
Image 26
80 Menu Mode

80 Menu Mode

 

 

 

 

 

 

Output Function No.

Enter the output function number to be defined (or 00 to exit)

 

Output Funct. #

 

(FA168CPS: 01-48

 

 

 

(00 = Quit)

 

01

 

 

 

 

(FA148CP: 01-24)

 

 

 

 

 

 

 

 

[] to continue; 00 to quit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary Screen

This screen displays a summary of the current output

 

01

A

E

P

Trig

 

[] to continue

programming (for this example, Zone List has been selected-this

 

?00

0

0

ZL=00

 

 

is the default screen).

 

 

 

 

 

 

 

A = Output Action; E = Triggering event; P = Partition;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trig = Trigger type

 

 

 

 

 

 

 

NOTE: A question mark in the summary screen indicates that the

 

 

 

 

 

 

 

device number shown has not been mapped. Use *79 Menu

 

 

 

 

 

 

 

mode to map the device.

 

 

 

 

 

 

Activated By

Select where the initiating event for this output definition is to

 

01 Activated By:

 

0 = delete

occur as follows:

 

Zone List

 

 

 

 

 

1 = zone list (go to “A”)

If you enter “0,” the following prompt appears:

 

 

 

 

 

 

2 = zone type (go to “B”)

Delete?

 

 

 

 

 

 

 

3 = zone number (go to “C”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[] to continue

0 = NO, 1 = YES

 

 

 

 

 

 

 

 

 

 

Press 1 to delete this output definition. The system deletes the output function and any previous programming.

A

01 Zn List

1

Zone List

01-08 = zone list [] to continue

(prompt appears if zone list was selected)

Enter the desired zone list number associated with this output number. At the ENTER EVENT prompt, enter the zone list event that will activate this output

NOTE: Do not use pager zone lists 09-12 in output definitions.

Enter Event

Alarm 1

0 = restore; 1 = alarm;

2 = fault; 3= trouble

 

 

 

 

NOTE: For alarm, fault, and trouble, an event on ANY zone in the

 

 

 

 

list activates the output, but ALL zones in the list must be

 

 

 

 

restored before the output is restored.

 

 

 

 

 

 

Press [] to continue and skip to the “Output Action” prompt.

 

B

 

Zone Type

(prompt appears if zone type was selected)

 

 

 

 

See list at right for available

Enter the desired zone type associated with this output number.

 

01 Enter Zn type

 

 

 

zone types.

At the PARTITION prompt, enter the partition in which this zone

 

Perimeter

03

 

 

type will occur.

 

 

 

 

 

 

 

 

 

 

CHOICES FOR ZONE TYPES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

= Not Used

05

= Day/Night

12

= Monitor Zone

 

 

 

 

01

= Ent/Exit #1

06

= 24 Hr Silent

14

= Carbon Monoxide††

 

 

 

 

02

= Ent/Exit #2

07

= 24 Hr Audible

16

= Fire w/verification

 

 

 

 

03

= Perimeter

08

= 24 Hr Aux

23

= No Alarm Response

 

 

 

 

04

= Interior Follower

09

= Fire

24

= Silent Burglary

 

 

 

 

 

 

10

= Interior w/Delay

77

= Keyswitch Zone

 

 

 

 

 

 

 

 

 

81

= AAV Monitor Zone

 

 

 

 

 

 

 

 

 

90-91 = Configurable

 

 

 

 

CHOICES FOR SYSTEM OPERATION:

 

 

 

 

 

20

= Arming–Stay

36

= **At Bell Timeout***

58

= Duress

 

 

 

 

21 = Arming–Away

38 = Chime

 

60

= AAV

 

 

 

 

22

= Disarming

39

= Any Fire Alarm

 

61

= AVS/GSMV session begin§

 

 

 

 

31

= End of Exit Time

40

= Bypassing

 

62

= AVS/GSMV session end §

 

 

 

 

32

= Start of Entry Time

41

= **AC Power Failure

66

= Function Key†

 

 

 

 

33

= Any Burglary Alarm

42

= **System Battery Low 67

= Bell Fail

 

 

 

 

 

 

43

= Comm. Failure

 

68

= Telco Line Cut

 

 

 

 

 

 

52

= Kissoff

 

78

= Keyswitch Red LED

 

 

 

 

 

 

54

= Fire Zone Reset

 

79

= Keyswitch Green LED

**Use 0 (Any) for Partition No. (P) entry.

***Or at Disarming, whichever occurs earlier.

† Use *57 Menu Mode to assign the function key (function “07”).

††when used with an output function, the carbon monoxide zone type activates upon CO alarms only. Does not activate for trouble conditions. § automatically set when appropriate AVS Quick Command performed.

Note: In normal operation mode:

Code + # + 7 + NN Key Entry starts Device NN.

Code + # + 8 + NN Key Entry stops Device NN.

Enter the partition in which this zone type will occur.

 

01 Partition

0

= any partition; 1 = partition 1;

 

 

 

 

 

 

 

 

 

 

Any partition 0

2

= partition 2; 3 = common

Press [] to continue and skip to the “Output Action” prompt.

– 26 –

Page 26
Image 26
First Alert FA148CPSSIA manual Menu Mode, Output Function No, Summary Screen, Activated By, Zone List, Zone Type