93

Reports In Armed Period Per

 

Zone (Swinger Suppression)

 

Restrict Report Pairs:

 

0

= Unlimited Reports

 

1

= 1 report pair per zone per armed

 

 

period

 

2

= 2 report pairs per zone per armed

 

 

period

[1,0]

Restrict SIA-Compliant Controls:

Report Pairs Unlimited Reports Enable

Selection limits the number of alarm/alarm restore message pairs per zone sent to the CS in an armed period. Swinger suppression applies to burglary zones only.

SIA Guidelines: Must be set for option 1 or 2

SIA-Compliant Controls:

Restrict Report Pairs:

1 = 1 report pair; 2 = 2 report pairs

Unlimited Reports Enable:

0 = restrict reports to the setting in entry 1

1 = unlimited reports for zones listed in zone list 7; (use zone list 7 to enter those zones that require unlimited reporting; these zones ignore the setting in entry 1)

DOWNLOAD INFORMATION (94, 95)

94 Download Phone No.

Enter up to 20 digits, 0–9; #+11 for ''; #+12 for '#'; #+13 for a 2-second pause. Do not fill unused spaces. If fewer than 20 digits, exit field by pressing . To clear entries from field, press 94.

Enter the phone number of the downloading computer.

UL: downloading may be performed only if a technician is at the site. Up/downloading via the Internet has not been evaluated by UL.

95

Ring Count For Downloading

 

 

 

 

 

 

 

 

[15]

 

 

 

 

0 = Disable Station Initiated Download;

 

 

 

 

 

 

 

Refer to the chart below and program accordingly.

 

1–14 = number of rings (1–9, # +10 =10,

 

# +11 =11, # +12 =12, # +13 =13,

 

phone

answer

down-

Set field 95 to…

 

# +14 =14);

 

module

machine

loading

 

 

yes

no

no

1-14 (not 0)

 

15 = answering machine defeat

 

 

 

yes

yes

no

greater than rings set on answer machine

 

(# +15 =15).

 

 

 

 

 

 

 

(e.g., if ans. machine is 4 rings, set this

 

 

 

 

 

 

 

 

NOTE: Do not enter 0 if using 4286

 

 

 

 

 

field to 5). This allows access to the

 

Phone Module.

 

 

 

 

 

phone module if the answer machine is

 

 

 

 

 

 

 

off.

 

 

 

yes

no

yes

1-14 (not 0)

 

 

 

yes

yes

yes

15 (bypasses answer machine)

 

 

 

no

no

no

0

 

 

 

no

yes

no

0

 

 

 

no

no

yes

1-14

 

 

 

no

yes

yes

15

NOTE: If “15” is entered to bypass an answering machine, and a 4286 Phone Module is included in the system, you should note the following:

When calling in from an off-premises phone, the user should make the initial call, allow 1 or 2 rings only, then hang up, then call again. The phone module will now seize the line, and 2 long tones sound, followed by the usual voice prompt for the access code. If this procedure is not followed, phone module operation will not be possible.

96, 97 Initialize/Reset Defaults (These are commands, not data fields. See page 3.) 98, 99 Exit Commands (These are commands, not data fields. See page 3.)

PAGER OPTIONS (160- 172)

The system can send various reports to several pagers (FA168CPS = up to 4; FA148CP = up to 2). To program pager reporting, do the following:

1.Enter the pager phone number(s), preface characters, and pager report options in data fields *160 - *171.

2.Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers).

3.Make sure appropriate user open/close pager reports are enabled (see Security Codes section in User Guide). Users that perform actions in partition 1 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 1. Users that perform actions in partition 2 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 2.

4.If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master code + [#] [6] [4] then select event type 03). System must be armed for the Latchkey report to be sent.

5.If using a function key to manually send a message to a pager, use *57 Function Key Menu mode to define the key (function 01).

6.If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones associated with each pager (zone lists 9-12†).

FA148CP supports zone lists 9 and 10 only.

12 –

Page 12
Image 12
First Alert FA148CPSSIA manual ∗93, ∗95

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.