Arm Away/Stay Rpt Code

 

See above for entries.

[0,0,0,0,0,0]

Away Stay

Away Stay

Away Stay

Part. 1

Part. 2

Common

This option allows for independent programming of Away and Stay reports for each partition, including the common lobby.

NOTE: “OPEN” reports are not sent if the associated closing report is not enabled.

67

RF Trans. Low Bat Report Code

 

[00]

See above for entries.

Sent when a transmitter low-battery condition exists. UL: must be enabled if wireless devices are used

68

 

Cancel Report Code

 

 

See above for entries.

 

 

 

SIA-Compliant Controls:

[10]

 

 

 

Report enabled.

 

 

 

 

 

 

[00]

Sent upon disarming the system after an alarm condition was reported.

69

 

Recent Closing Report Code

 

 

Not applicable to FA148CP/FA168CPS

 

 

See above for entries.

 

 

 

 

 

 

 

 

SIA-Compliant Controls:

 

 

 

 

Always enabled.

 

 

 

 

 

 

 

 

 

 

[11]

SIA-Compliant Controls: Field does not apply to other controls. Similar to the Exit Error condition described in field *59, but occurs if any burglary zone is faulted within two minutes after the initial exit delay expires. Disarming the system within the two minutes stops the alarm sound and displays "ALARM CANCELED " or "CA" and faulted zone number. No message is sent to the Central Monitoring Station. If the system is not disarmed within two minutes, the alarm sound continues and a “recent closing” and a “zone alarm” message are sent to the Central Monitoring Station (after dial delay expires).

RESTORE REPORT CODES (70 – 76)

70

Alarm Restore Rpt Code

 

See above for entries.

[0]

Alarm restore signals indicate that respective alarm zone(s) are no longer faulted. Alarm restore reports are sent to the central station at bell timeout (field *33), if the zone(s) in alarm are actually restored to a non-faulted state at that time. Otherwise, alarm restore report(s) for respective alarm zones are sent when the system is disarmed.

See UL System Reporting Note above *59.

If Reports Per Armed Period Per Zone (*93) is also programmed, the system will report alarm and restore codes as described above until the “Reports Per Armed Period” count is reached. Disarming and rearming will reset the “Reports Per Armed Period” count.

 

71

Trouble Restore Rpt Code

 

 

 

 

[00]

 

 

 

See above for entries

Sent when a trouble in a zone is restored and code + OFF performed.

 

 

 

 

 

 

See UL System Reporting Note above *59.

 

 

 

 

 

 

 

 

 

Bypass Restore Rpt Code

 

 

 

 

72

 

 

 

 

[00]

 

 

 

See above for entries.

Sent when a zone that has been bypassed is unbypassed.

 

 

 

See UL System Reporting Note above *59.

 

73

AC Restore Rpt Code

 

 

 

 

[00]

 

 

 

See above for entries.

 

 

 

 

 

Sent after AC power has been restored after an AC power outage.

 

 

 

 

 

 

See UL System Reporting Note above *59.

 

 

 

 

 

 

 

 

 

Low Bat Restore Rpt Code

 

 

 

 

74

 

 

 

 

[00]

 

 

 

See above for entries.

Sent after a system low-battery condition is restored to normal.

 

 

 

See UL System Reporting Note above *59.

75

RF Trans. Lo Bat Rst Rpt Code

 

See above for entries.

[00]

Sent when a transmitter’s low battery condition is restored (i.e., new battery installed).

UL: must be enabled if wireless devices are used. See UL System Reporting Note above *59.

76

Test Restore Rpt Code

 

[00]

See above for entries.

This is sent when the Test mode is exited or upon timeout (4hrs). See UL System Reporting Note above *59.