| Loop Number Change | NOTE: If the [C] key is used to copy the previously enrolled |
| 10 INPUT S/N | L | |||||
| [∗] to continue | serial number, the cursor will move to the Loop column (L) with | |||||
| A022 - 4064 |
| ? | ||||
|
|
| the previous serial number displayed, and display a highlighted | ||||
|
|
|
|
|
|
| question mark for the loop number. |
|
|
|
|
|
|
| Enter the loop number and press [✱]. The system will now |
|
|
|
|
|
|
| check for a duplicate serial/loop number combination. |
|
|
|
|
|
| Confirmation Option | This prompt will only appear if you answered “Yes” at the first |
| XMIT TO CONFIRM | ||||||
| [∗] to continue | prompt in this section. | |||||
| PRESS ✱ TO SKIP | ||||||
|
| The system will enter a confirmation mode so that the operation | |||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| of the actual programmed input can be confirmed. |
|
|
|
|
|
|
| Activate the loop input or button that corresponds to this zone. |
|
|
|
|
|
| If Serial or Loop | If the serial number transmitted does not match the serial |
| Entd A022 - 4063 1 | ||||||
| Numbers do not match | number entered, a display similar to the one shown appears. If | |||||
| Rcvd A022 - 4064 | 1 | |||||
| after activating the | the loop number does not match, it will also be displayed. | |||||
|
|
|
|
|
| ||
|
|
|
|
|
| If so, activate the loop input or button on the transmitter once | |
|
|
|
|
|
| transmitter | |
|
|
|
|
|
| again. If a match is not obtained (i.e., summary display does not | |
|
|
|
|
|
| [∗] to continue | |
|
|
|
|
|
| appear), press the [#] key twice and then enter (or transmit) the | |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| correct serial number. |
|
|
|
|
|
| To Delete a Serial No. | To delete an existing serial number, enter 0 in the loop number |
| 10 INPUT S/N: | L | |||||
| 0 = delete serial number | field. The serial number will change to 0's. | |||||
|
| A000 - 0000 | 0 | ||||
|
| # = undo deletion | If 0 was entered in error, simply | ||||
|
|
|
|
|
| [∗] to continue | press [#], and the serial number will return to the display. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Summary Screen | If the serial number transmitted matches the serial |
| Zn | ZT | RC | In: | L | ||
| [∗] to continue | number entered, the keypad will beep 3 times and a | |||||
| 10 | 03 | 10 | RF: | 1s | ||
|
| summary display will appear, showing that zone's | |||||
|
|
|
|
|
|
| programming. Note that an “s” indicates that a |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| transmitter’s serial number has been enrolled. |
|
|
|
|
|
|
| Press [∗] to accept the zone information and continue. |
|
|
|
|
|
| Alpha Descriptors | If you want to program descriptors for zones now, enter 1 (Yes) |
| PROGRAM ALPHA? | ||||||
| 0 = no | and refer to the ∗82 Descriptor Programming section for | |||||
| 0 = NO 1 = YES | 0 | |||||
| 1 = yes | available descriptors. | |||||
|
|
|
|
|
|
|
|
[∗] to continue
ENTER ZN NUM. (00 = QUIT) 11
Next Zone Number
[∗] to continue; 00 = quit
If 0 (No) was entered above, the system will return you to the ENTER ZN NUM. prompt for the next zone.
When all zones have been programmed, enter 00 to quit
Completing Zone Programming
•When you have finished programming all zones, test each zone using the system’s TEST mode.
•Do not use the Transmitter ID Sniffer Mode for checking wireless transmitting devices, as it will only check for transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop.
∗58 EXPERT ZONE PROGRAM MODE
(press ∗58 while in Data Programming mode)
This method is designed for use by installers with previous experience in programming First Alert Professional control panels. This mode is also used to program wireless keys using
SET TO CONFIRM? 0 = NO 1 = YES 0
Confirm?
0= no; 1 = yes; [∗] to continue
Select whether you want confirmation of wireless device enrollment. (See “XMIT TO CONFIRM” prompt later in this section.) We recommend that you confirm the programming of every transmitter.
If 1 (Yes) is entered, you will be prompted to confirm each transmitter after entering the serial and loop numbers (at the “XMIT TO CONFIRM” prompt later).
Zn ZT P RC HW: RT
01 09 1 10 EL 1
Summary Screen
00 = quit
[D]to go to prompts for wireless key programming templates
A summary screen appears, showing zone 1’s currently programmed values.
Enter the zone number being programmed, then press [∗], which displays a summary screen for that zone and the cursor moves to the Zone Type location. The cursor then automatically moves to the next locations after each entry is made.
If programming a wireless key, press the [D] key then skip to the Wireless Key Programming Templates section following this section. When [D] is pressed, you can choose from a series of preset templates for easy programming of wireless key zones.
When all zones have been programmed, press 00 at this prompt to quit this menu mode.