First Alert FA148CPSSIA manual Output Type, Unit Number, Module Address, Relay Position, Component

Models: FA148CPSSIA

1 40
Download 40 pages 18.24 Kb
Page 25
Image 25
Output Type

XXOUTPUT TYPE

DELETE0

Output Type

0 = delete

1 = relay on 4204/4229 module

2 = Powerline Carrier device (X-10)

[] to continue

Select whether this is a relay or a Powerline Carrier (X-10) device.

If Powerline Carrier is selected, go to “A” prompt. If relay is selected, skip to “B” prompt.

“A”

XX UNIT No.

yy

Unit Number

01-16 = predefined address [] to continue

(prompt appears if X-10 is selected)

Enter the unit code (set at the device) and press []. The system returns to the Output Number prompt.

“B”

XXMODULE ADDR

07-15yy

Module Address

07-15 = predefined address [] to continue

(prompt appears if relay is selected)

Enter the predefined address for this module as listed below. Make sure the module’s DIP switches are set to the selected address.

Module Addresses

Address

Module

07

1st 4229 (with zones 09-16)

08

2nd 4229 (with zones 17-24)

09

3rd 4229 (with zones 25-32)

10

4th 4229 (with zones 33-40)

11

5th 4229 (with zones 41-48)

12

1st 4204

13

2nd 4204

14

3rd 4204

15

4th 4204

† These addresses apply to FA168CPS only.

 

 

Relay Position

This is the actual (or physical) relay number with respect to the

XX REL POSITION

 

 

1-4 = relay position

Relay Module upon which it is located. For 4204 modules, relay

1-4

zz

[] to continue

numbers are 1-4. For 4229 modules, relay numbers are 1-2.

 

 

 

 

 

The system returns to the Output Number prompt for

 

 

 

programming the next device.

80 OUTPUT FUNCTION MENU MODE

(press 80 while in Programming mode) The Output Definition Worksheet is on page Error! Bookmark not defined.. Use this mode to program output function definitions (up to 48 functions) that provide automated control of any of the output devices, based on events occurring on individual zones or zones with certain zone types. Each output definition is identified by an output function number, and includes the following components:

Output Definition Components

Component

Description

Output Function No.

A reference number that defines an output’s characteristics.

Activated By

Determines whether the initiating event occurs on a zone, a zone list, or a zone type.

Event

Event that triggers the output action. Can be an event occurring on a specific zone number or a

 

zone list, or a specific zone type.

Partition

If the output is activated by zone type, this defines the partition in which the programmed event is

 

to cause the device action.

Output Action

Defines the action of the relay/X-10 device when the defined event occurs. Can close for 2

 

seconds, stay closed until reset, continuously pulse (1-second close-open-close-open, etc.),

 

toggle the device state, or activate for a defined duration (set in data field *177).

Output No.

Assigns this function to a specific output number (defined in *79 Menu Mode). This is the output

 

number that will perform this function upon the triggering event. Note that each defined function is

 

associated with only one output number. This means that if more than one output device needs to

 

perform this particular function, you need to define another output function number with the same

 

attributes, but assign the appropriate output number. (i.e. output devices can be assigned more

 

than one function number, but each function number can only be assigned a single output

 

number.

For example, if you want to pulse a strobe light upon fire alarms on zone 4 using a relay mapped to output number 2 (as programmed in *79 Menu Mode), program the following in *80 Menu Mode:

Prompt

 

Entry

Output Funct. #

=

01

(assuming this is the first output function)

Activated By:

=

3 (zone number)

Enter Zn No.

=

04

(requires 2-digit zone numbers)

Output Action

=

3 (continuous pulse)

Output Number

=

02

(device mapped in *79 Menu Mode)

 

 

 

– 25 –

Page 25
Image 25
First Alert FA148CPSSIA Output Type, Unit Number, Module Address, Relay Position, Output Definition Components, Prompt