Deleting a Zone

To save the zone list, enter 0 and the system returns to the Zone

 

01 Delete Zone?

 

 

 

0 = don’t delete zones

List No. prompt.

 

0 = No 1 = Yes

0

 

1 = go to next prompt to

To delete a zone or zones in a zone list, enter 1 to continue.

 

 

 

delete zones

 

 

 

 

 

 

 

 

[] to continue

 

 

 

 

Delete the Zone

Enter each zone to be deleted from the list, followed by []. After

 

01 Zn to Delete?

 

 

 

01-64= zones to be

all zones to be deleted are entered, enter 00 to return to the

 

(00 = Quit)

00

 

deleted from list

Zone List No. prompt so that another list can be programmed, if

 

 

 

desired.

 

 

 

 

 

 

followed by [] to

 

 

 

† FA168CPS = 01-64; FA148CP = 01-06, 09-34, 49-56.

 

 

 

accept each zone

 

 

 

 

 

 

 

00 to continue

 

82 ALPHA DESCRIPTOR MENU MODE

The system lets you assign zone descriptors for protection zones, keypad panics, and RF receiver supervision faults. Each description can be composed of a combination of up to 3 words selected from a vocabulary of words stored in memory (see Alpha Vocabulary List page). In addition, up to 10 installer-defined words can be added to those already in memory, plus 3 additional words can be assigned as partition descriptors. Thus, when an alarm or trouble occurs in a zone, an appropriate description for that zone's location can be displayed at the keypad. Zone descriptors are recommended for systems using Alpha display keypads, and are necessary if a 4286 Phone Module is used.

NOTE: You can also enter zone descriptors when the zone is being defined in 56 Menu mode.

4286 NOTE: If using a 4286 Phone Module, select from those words in the Alpha Vocabulary List shown in boldface type. The phone module will not provide annunciation of the other words.

If a Phone Module is added to an existing system, the Alpha descriptors presently in the system should be reprogrammed, selecting from those words shown in boldface type in the Alpha Vocabulary List. The phone module will not provide annunciation of any other words.

82 Menu Mode

 

 

 

Program Alpha

The “Program Alpha ?” prompt will appear. Press 1 to continue.

 

Program Alpha ?

 

0 = no (quit Alpha mode)

 

 

0=No, 1=Yes

00

 

 

1 = yes

 

 

 

 

[] to continue

 

 

 

 

 

 

 

 

Custom Words

The “Custom Words” prompt will appear.

 

Custom W ords ?

 

0 = no

Press 0 to program standard alpha descriptors from the fixed

 

0=No, 1=Yes

00

 

1 = yes

vocabulary. The system then automatically displays the descriptor

 

 

 

 

for zone 1.

 

 

 

 

 

 

 

 

Press 1 to define custom words (see “Adding Custom Words”).

 

 

 

Summary Screen

Note that this is a “Summary mode,” and that no entries can be

 

ZN 01

 

 

 

[] to continue to edit mode

made. Entries can be made only when the display contains a

 

 

 

 

 

 

[#] = return to Program

flashing cursor, which signifies Edit mode.”

 

 

 

 

 

 

Alpha prompt (to quit)

To exit the Alpha Descriptor mode, press + 0 + 0 at the

 

 

 

 

summary display.

 

 

 

Edit Mode – Flashing

Descriptor screen for zone 1 appears. To program a descriptor

 

ZN 01

 

 

 

Cursor

(up to 3 words) for a zone, do the following:

 

 

 

to edit = zone number then

1. Enter the desired zone number (existing descriptor, if any, is

 

 

 

displayed) and press [], then enter the zone number again to

 

 

 

 

 

 

 

 

 

[], then zone

start edit mode (flashing cursor appears).

 

 

 

number again

2. a. Press [#] plus the 3-digit number from the Alpha Vocabulary

 

 

 

6 = save word and go to

List for the first word.

 

 

 

next word in a

b. Press [6] to accept the word and move the cursor for the next

 

 

 

descriptor

word in the descriptor.

 

 

 

8 = save descriptor and go

3. Repeat steps 2a and 2b for the second and third words (if used).

 

 

 

4. When all words for that descriptor have been entered, press [8]

 

 

 

to next zone

 

 

 

to save the descriptor for that zone. The summary screen

 

 

 

 

 

 

 

[#] = return to Program

displays for that zone and the flashing cursor disappears.

 

 

 

Alpha prompt (to quit)

5. Press [] at the summary screen and repeat steps 1-4 to

assign a descriptor for the next zone.

6. When all descriptors have been entered, press [#]) at the last descriptor summary screen to return to the PROGRAM ALPHA? prompt. Enter 0 (no) at the prompt to exit this mode and return to Data Field mode.

– 28 –

Page 28
Image 28
First Alert FA148CPSSIA manual ∗82 Alpha Descriptor Menu Mode

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.