Zone Programming

Zn ZT P RC IN: L

10 00 1 10 RF 1

Zone Programming

ZT = see Zone Type chart shown in *56 Menu Mode “Zone Type” prompt

P = partition 1, 2, 3 (common);

RC = 1 (send CID report); 0 (no report)

IN = input type; L = loop number [] to continue

A summary screen with the selected zone’s current programming appears.

Begin programming zone information as follows:

Enter Zone Type (ZT), Partition (P), Report Code (RC; 0-9 only; use *56 mode to enter hex codes), and Input Device Type (IN)* sequentially, but not the Loop No. (L).

Use the [A] (Advance) and [B] (Back) keys on the keypad to move the cursor within the screen.

Use the [C] key to copy the previous zone’s attributes.

Press [] to save the programming and continue to the serial number/loop number prompt. If needed, you can press the [#] key to back up without saving.

*If HW (hardwired) or AW (Auxiliary) is entered for Input Device Type, the next screen will be similar to the prompt shown, except that HW or AW will be displayed under “IN”.

If RF, BR, or UR is entered, a prompt for Serial and Loop number will be displayed, as described in 56 Menu mode section.

When done, the display returns to the initial summary screen prompt to let you program the next zone.

To exit this mode, enter 00 at the Summary Screen prompt.

WIRELESS KEY PROGRAMMING TEMPLATES

(press the [D] key from *58 Menu mode Summary Screen)

This procedure programs the wireless keys, but a key is not active for arming/disarming until it is assigned to a user number (see System Operation section, Assigning Attributes Command in the User Guide).

TEMPLATE ?

1–61

Template Number

1–3 = 5804 templates; 4–6 = 5804BD templates

Enter Template number 1–6 (see chart on next page).

See the defaults provided for each template in the chart that follows these procedures.

Select from templates. Press [] to display template (1 shown selected).

NOTE: If necessary, press [#] to back up and re-enter template number.

Press [#] if you want to return to *58 Menu mode summary screen.

L

01

02

03

04

T

23

22

21

23

 

 

 

 

 

Template Display

When [] is pressed, the selected template will be displayed.

 

 

Top line of display represents loop numbers; bottom line

 

 

represents zone type assigned for each loop.

 

Press [] to accept template.

 

 

 

Partition

Enter the partition in which the key is to be active, then press

 

PARTITION

 

 

 

FA168CPS. 1 = partition 1;

[] to continue.

 

 

1

 

 

2 = partition 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start Zone Number

The system will search for the highest available consecutive

 

ENTER START ZONE

 

 

4-zone group (the four zones in the case of the 5804 and

 

00 = QUIT

36

 

 

 

5804BD), and display the lowest zone number of the group.

 

 

 

 

 

 

 

 

If you want to start at a different zone, enter the zone desired,

 

 

 

 

and press []. If that zone number is displayed, the system

 

 

 

 

has the required number of consecutive zones available,

 

 

 

 

beginning with the zone you entered. If not, the system will

 

 

 

 

again display a suggested zone that can be used.

 

 

 

 

If the required number of consecutive zones is not available

 

 

 

 

at all, the system will display “00”.

 

 

 

 

To quit this mode and return to *58 Menu mode, enter 00 at

 

 

 

 

this prompt.

 

 

 

 

Press [] to accept.

INPUT S/N

L

AXXX-XXXX

 

 

Serial Number

Manually enter the serial number printed on the label for the

 

wireless key or press and release the button to transmit its

 

serial number.

 

Press [] to accept the serial number. The system will check

 

for a duplicate.

 

If necessary, press the [#] key to back up without saving, and

 

re-enter the serial number.

 

Use the [A] key to move forward within the screen, and the

 

[B] key to move backward.

– 21 –

Page 21
Image 21
First Alert FA148CPSSIA Zone Programming, Template Number, Template Display, Partition, Start Zone Number, Serial Number