File and Message Format

Table 2: Common Elements of Audit Messages (cont.)

Code

Type

Description

 

 

 

ANID

UI32

Node ID—The grid node ID assigned to the service that generated

 

 

the message. Each service is allocated a unique identifier at the time

 

 

the HP Medical Archive is configured and installed. This ID cannot

 

 

be changed.

 

 

 

AMID

FC32

Module ID—A four-character identifier of the module ID that gen-

 

 

erated the message. This indicates the code segment within which

 

 

the audit message was generated.

 

 

 

ASQN

UI64

Sequence Count—A counter that is incremented for each generated

 

 

audit message on the grid node (ANID). This counter is reset to zero

 

 

at service restart. It can be used for consistency checks to ensure that

 

 

no audit messages have been lost.

 

 

 

9

HP Medical Archive

Page 20
Image 20
HP Medical Archive Solution manual Anid, Amid, Asqn