HP Medical Archive Solution manual SADE-Security Audit Enable, SCMT-Object Store Commit, Aeun

Models: Medical Archive Solution

1 79
Download 79 pages 27.2 Kb
Page 68
Image 68

Message Reference

Table 54: SADD—Security Audit Disable Fields (cont.)

Code

Field

Description

 

 

 

AEUN

User Name

The user name that executed the command to disable

 

 

audit logging.

 

 

 

The message implies that logging was previously enabled but has now been disabled. This is typically only used during bulk ingest to improve system performance. Following the bulk activity, auditing is restored (SADE) and the capability to disable auditing is then perma- nently blocked.

SADE—Security Audit Enable

This message indicates that the originating service (node ID) has restored audit message logging; audit messages are again being col- lected and delivered.

Table 55: SADE—Security Audit Enable Fields

Code

Field

Description

 

 

 

AETM

Enable Method

The method used to enable the audit.

 

 

 

AEUN

User Name

The user name that executed the command to enable

 

 

audit logging.

 

 

 

The message implies that logging was previously disabled (SADD) but has now been restored. This is typically only used during bulk ingest to improve system performance. Following the bulk activity, auditing is restored and the capability to disable auditing is then permanently blocked.

SCMT—Object Store Commit

Grid content is not made available or recognized as being stored until it has been committed - meaning it has been stored persistently. Persis- tently-stored content has been completely written to disk, and has

57

HP Medical Archive

Page 68
Image 68
HP Medical Archive Solution manual SCMT-Object Store Commit, Aeun, SADE-Security Audit Enable Fields