HPMA Audit Message Reference

When an unknown or unexpected file is detected in the object store and moved to the “garbage” directory, this message is issued.

Table 59: SVRU—Object Store Verify Unknown Fields

Code

Field

Description

 

 

 

 

FPTH

File Path

The full path to the unexpected file’s original location.

 

 

 

 

 

 

 

 

 

 

 

 

The “SVRU - Object Store Verify Unknown” audit message should be moni- tored closely. It means unexpected files were detected in the object store. This situation should be investigated immediately to determine how the files were created, as it can indicate attempts to tamper with content or impending hardware failures.

SYSD—Node Stop

When an HP Medical Archive grid service is stopped gracefully, this message is generated to indicate the shutdown was requested.

Table 60: SYSD—Node Stop Fields

Code

Field

Description

 

 

 

RSLT

Clean Shutdown

The nature of the shutdown:

 

 

SUCS—System was cleanly shutdown.

 

 

 

The message does not indicate if the host server is being stopped, only the reporting service.

SYSU—Node Start

When an HP Medical Archive grid service is started, this message is generated and indicates if the previous shutdown was clean (com- manded) or disorderly (unexpected).

Table 61: SYSU—Node Start Fields

Code

Field

Description

 

 

 

RSLT

Clean Shutdown

The nature of the shutdown:

 

 

SUCS—System was cleanly shutdown.

 

 

DSDN—System was not cleanly shutdown.

 

 

 

60